2TLC172245M0201, rev. B
18
www.abb.com/jokabsafety
2013-04-22
7 Technical data
Manufacturer
Address
ABB AB / JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Electrical characteristics
Utilization category
AC-15 A300 3A
Thermal current
10A
Rated insulation/withstand voltages
600 VAC/2500 VAC
LED 2 supply voltage
24VDC +/-10%
Solenoid power consumption
12 W (MKey8M, inrush current 1.5A)
Solenoid voltage (by part number)
24VDC +/-10% or /-10%
Auxiliary Contact 33/34 (selectable with
LED2)
230VAC/DC 500mA max. (Not on MKey8M)
Auxiliary Contact 43/44
230VAC/DC 500mA max. (MKey8M 24V 200mA max.)
General
Travel for positive opening
10 mm
Actuation Frequency
2 cycle/sec
Actuator entry minimum radius
175 mm Standard Key
100 mm Flexible Key
Protection class
MKey8, MKey8M, MKey8ER: IP67
MKey8Z: IP67, IP69K
Ambient temperature
MKey8, MKey8ER, MKey8Z: -25…+80°C
MKey8M: -25…+40°C
Size
See drawing
Conduit entries
3 x M20 x 1.5
Material
MKey8, MKey8M, MKey8ER: Die cast painted red
MKey8Z: Stainless steel 316
Fixing
Body: 4 x M5
Actuator: 2 x M5
Maximum approach / withdrawal speed 600 mm/s
Holding force
2000N (Max.)
Vibration
IEC 68-2-6, 10-55 Hz+1 Hz,
Excursion: 0.35 mm, 1 octave/min