36
L ST 3 0 0 |
CO M PAC T U LT R A S O N I C L E V EL T R A N SM I T T ER | L S T 3 0 0 – EN R E V. E
Menu / Parameter
Value range
Description
Device Type
161.00
Display of the HART device type
LST300 = 161
Device ID
1.0000
Display of the HART device ID
Menu: Diagnostics
Menu / Parameter
Value range
Description
Diagnostics
Signal Waveform
-
-
True Echo Detection
-
Status Monitor
-
Simulation
-
Device Run Time
-
Diagnostics / True Echo Detection
Start Tank Profiling
-
Start tank profiling
Select True Echo
1 to 5
Select true echo number
Disable Tank Profiling
-
Disable tank profiling
Tank Profiling Status
Idle
Initialize
Pulsing
Processing
Finish
Present tank profiling status
Threshold Start
Max 2500.0 mV
Min 0.0000 mV
The voltage of the threshold at the first threshold point . This point is where the
blanking distance ends .
Threshold Middle
Max 2500.0 mV
Min 0.0000 mV
The voltage of the threshold at the middle threshold point
Threshold End
Max 2500.0 mV
Min 0.0000 mV
The voltage of the threshold at the last threshold point . This point is at the Empty
Distance .
Diagnostics / Status Monitor
Gain
Display only
The Gain value of the sensor in the last measurement
Pulse Number
Display only
The Number of pulses of the sensor in the last measurement
Power Mode
Display only
The Power Mode of the sensor in the last measurement
Power Change Ratio
Display only
The number of power changes in the last minute
Echo Number
Display only
The number of echoes in the last measurement
Present Blanking
Display only
Present blanking value
Current Output
Display only
The analog output in mA
Signal Level
Display only
Average size in mV of all echoes that crossed the threshold in the last measurement
Max Signal Level
Display only
Maximum signal level in mV in the last measurement
Noise Level
Display only
Average size in mV of all echoes that did not cross the threshold in the last
measurement
Max Noise Level
Display only
Maximum noise level in mV in the last measurement
Signal Noise Ratio
Display only
Ratio of signal to noise
Sensor Temperature
Display only
The temperature as measured by the internal temperature sensor
Temperature Too Low
Display only
Alarm for temperature too low
Temperature Too High
Display only
Alarm for temperature too high
Beyond Empty Distance
Display only
Alarm for distance beyond empty distance
Almost Full
Display only
Alarm for distance close to blanking
Echo Too large
Display only
Alarm for echo too large
Echo Too Small
Display only
Alarm for echo too small
Lost Echo
Display only
Alarm for single echo lost
Lost Signal
Display only
Alarm for echo lost
Noise Alarm
Display only
Alarm for noise
Summary of Contents for LST300 Series
Page 26: ...26 LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E ...
Page 27: ...LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E 27 ...
Page 28: ...28 LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E ...
Page 59: ...LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E 59 Note ...