Specifications (Refer to LMT100/200 Datasheets for Details)
Electronic transmitter:
Repeatability

± 0.005% of Full Scale or 0.305 mm (0.012 in), whichever is greater

Non-linearity

± 0.01% of Full Scale or 0.864 mm (0.034in), whichever is greater

Measuring accuracy

± 0.01% of Full Scale or 1.27 mm (0.050 in), whichever is greater

Supply voltage

12 to 42 Vdc - 4-20mA HART loop powered

Output/Communications

4-20mA HART7®

User Interface

Interactive display, DTM, EDDL with NE107 messaging

Power consumption

4-20mA

at 36.0 Vdc - 3.6mA 0.13 watts; 21mA 0.76 watts
at 12.0 Vdc - 3.6mA 0.043 watts; 21mA 0.25 watts

HART mode (4.0mA)

at 36.0 Vdc 0.144 watts
at 12.0 Vdc 0.048 watts

Ambient temperature

-40 to 85°C (-40 to 185°F) Ambient

Humidity

0 to 100% RH

Electrical connection

Two M20 x 1.5 or two 1/2in. FNPT, adapters and bus connectors also available

Ingress protection

IP66, NEMA 4X

Sensor tube:

Material

316/L Stainless Steel

Process temperature

LMT100: -195.5 to 121.1°C (-320 to 250°F)

Process pressure

LMT100: -1.0 to 124.1 bar @ 149°C (-14.7 to 1800 psig @ 300°F)

Probe length

LMT100: 304.8mm to 9.14m (1 to 30ft) / LMT200: 304.8mm to 15.24m (1 to 50ft)

 

Summary of Contents for LMT100

Page 1: ...ABB MEASUREMENT ANALY TICS COMMISSIONING INSTRUCTIONS LMT Series Magnetostrictive level transmitter LMT100 200 models Quick Start Guide K TEK Level products Measurement made easy...

Page 2: ...2 LMT SERIES MAGNETOSTRICTIVE LEVEL TR ANSMITTER LMT100 200 MODELS CI LMT100 200 EN REV B Sales Service Contents 1 Electrical Connections 4 2 Mounting 4 3 Easy Setup 5...

Page 3: ...r systems according to safety engineering standards for electrical circuits high pressures and aggressive media Training or instruction in accordance with safety engineering standards regarding mainte...

Page 4: ...lator 5 PLC DCS 6 HART Handheld terminal 7 External indicator 8 External earthing terminal 9 Terminal for external indicator 0 Laptop LMT100 Transmitters installations A Installed in external chambers...

Page 5: ...y Setup menu and press LRV is the lower range value which corresponds to 4 mA current out value 7 Set URV in the Easy Setup menu and press URV is the upper range value which corresponds to the 20 mA c...

Page 6: ...RT mode 4 0mA at 36 0 Vdc 0 144 watts at 12 0 Vdc 0 048 watts Ambient temperature 40 to 85 C 40 to 185 F Ambient Humidity 0 to 100 RH Electrical connection Two M20 x 1 5 or two 1 2in FNPT adapters and...

Page 7: ...LMT SERIES MAGNETOSTRICTIVE LEVEL TR ANSMITTER LMT100 200 MODELS CI LMT100 200 EN REV B 7...

Page 8: ...illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB Copyright 2018 ABB A...

Reviews: