background image

6   

OI/LMS100-EN Rev. A | 

LMS100 Magnetic Level Gauge Switch 

5.2 Requirements for Hazardous Locations

5.2.1 General Guidelines

1. WARNING! 

MAKE SURE ALL CIRCUITS ARE DE-ENER-

GIZED PRIOR TO INSTALLATION.

2.  The LMS100 has been evaluated as an Installation 

(Overvoltage) Category 1 / Pollution Degree 2 apparatus 
per IEC 1010.

3.  The maximum altitude of operation is 6560 feet (2000 

meters).

4.  The LMS100 is designed with both internal and external 

protective earth (ground) terminals. 

5.  Housing and cover are made from 316L SS. Assess 

material suitability for the target environment 
before deploying.

6.  Additional flamepath information available upon request.

7.  Product label may be susceptible to electrostatic charge 

buildup in Group III environments.  Care should be taken 
to prevent the buildup of electrostatic charge.  Clean 
only with a damp cloth

8.  Do not torque any attached conduits, thread adapters, 

reducers, elbows, or cable glands beyond the manu-
facturer’s recommended installation torque. Torque 
requirements for the LMS100’s optional thread adapters 
are listed below.

Option

Description

Recommended 

Torque

U8

M20 adapter 316 SS

32.5 Nm

E8

1/2 inch by 1/2 inch 

NPT elbow

35 Nm

E9

1/2 inch NPT by M20 

elbow

35 Nm

 

5.2.2 Nameplate Marking Procedure (Declaration of Protec-
tion Concept)

Before installing the switch, permanently indicate the protec-
tion concept associated with the hazardous area by marking the 
corresponding box on the product label.  Only one box shall be 
marked.  The chosen protection concept cannot be altered and 
shall govern the use of the product until end of life.  If more than 
one protection concept is marked, the switch must be removed 
from the hazardous area immediately.

FM/FM-C Name Plate

 

 

1

2

3

4

A

B

C

D

1

2

3

4

A

B

C

D

The information contained herein is

proprietary to and considered a trade

secret of ABB Inc., and shall not be

reproduced, in whole or

in part, without the written authorization

of ABB Inc.

Lang.:

Prepared by:

Title:

Part No.:

Doc. Type:

Date:

Rev.:

Sheet:

Drawing No.:

Approved by:

PA/MP/LM

Resp.

K-TEK PRODUCTS

18321 SWAMP ROAD

PRAIRIEVILLE, LA. 70769 USA

EN

LMS100 FM/FM-C

NAMEPLATE

Norman W Guidry

Eric Fauveau

         08/05/14

3KXL000391U0200

3KXL000391U0209

   -

ARTWORK DRAWING

       1 of 1

REV

DESCRIPTION

APPROVED

DATE

-

ECN0915

E.F.

-

CRITICAL / SCHEDULE DOCUMENT

NO MODIFICATION PERMITTED WITHOUT APPROVAL

FROM AGENCY / NOTIFIED BODY

NOTES:
1. LABEL MATERIAL:

   - SUBSTRATE LAYER: BRADY B-428
   - OVERLAMINATE LAYER: BRADY B-111
   - ADHESIVE LAYERS: HIGH PERFORMANCE ACRYLIC
2.  LABEL TEMP. RANGE: -40°C TO 150°C (OUTDOOR)
3.  LABEL MUST BE RESISTANT TO OCCASIONAL EXPOSURE TO

PETROLEUM SOLVENTS.

4.  REFER TO 3KXL000391U0018 FOR MARKING PROCEDURE.
5.  DIMENSIONS ARE IN INCHES [MM].

SUBSTRATE LAYER

ADHESIVE LAYER

ADHESIVE LAYER

OVERLAMINATE LAYER

3KXL000391U0200 LAYERS

3KXL000460U0100

3KXL000461U0100

PRO

DE

3KXl

!

L

4.000

.700

K-TEK PRODUCTS

250V MAX

1A MAX

60VA MAX

(NON-IS/NI)

TYPE 4X; NO ACIDIC ATMOSPHERES  / AUCUN ATMOSPHERES  ACIDES; IS / NI

PER CONTROL DWG 3KXL130100G0022;  CONDUIT SEAL REQUIRED  WITHIN

2 IN / SCELLEMENT EXIGE SUR CONDUIT A 50 MM; -40°C

T

A

70°C

CLII DIV2 GP EFG T6; CLIII T6
CLI Zn2 AEx nC IIC T6...T1
Ex nC IIC T6...T1 Gc

NI: CLI DIV2 GP ABCD T6

CLII GP EFG T6; CLIII T6
CLI Zn1 AEx d IIC T6...T1
Ex d IIC T6...T1 Gb
Zn21 AEx tb IIIC T85°C...T450°C

XP: CLI GP ABCD T6

CLII GP EFG T6; CLIII T6
CLI Zn0 AEx ia IIC T6...T1
Ex ia IIC T6...T1 Ga
Zn20 AEx ia IIIC T85°C...T450°C

IS: CLI GP ABCD T6

FM

APPROVED

C

US

MADE IN USA

LMS100.XX.XX.XX.XX
SN: 3K650000000000
MAGNETIC SWITCH

SEE MANUAL

OI/LMS100

!

!

K-TEK PRODUCTS

250V MAX

1A MAX

60VA MAX

(NON-IS/NI)

TYPE 4X; NO ACIDIC ATMOSPHERES / AUCUN ATMOSPHERES ACIDES; IS / NI

PER CONTROL DWG 3KXL130100G0022;  CONDUIT SEAL REQUIRED WITHIN

2 IN / SCELLEMENT EXIGE SUR CONDUIT A 50 MM; -40°C

T

A

70°C

CLII DIV2 GP EFG T6; CLIII T6
CLI Zn2 AEx nC IIC T6...T1
Ex nC IIC T6...T1 Gc

NI: CLI DIV2 GP ABCD T6

CLII GP EFG T6; CLIII T6
CLI Zn1 AEx d IIC T6...T1

Ex d IIC T6...T1 Gb

Zn21 AEx tb IIIC T85°C...T450°C

XP: CLI GP ABCD T6

CLII GP EFG T6; CLIII T6
CLI Zn0 AEx ia IIC T6...T1

Ex ia IIC T6...T1 Ga

Zn20 AEx ia IIIC T85°C...T450°C

IS: CLI GP ABCD T6

FM

APPROVED

C

US

MADE IN USA

LMS100.XX.XX.XX.XX

SN: 3K650000000000

MAGNETIC SWITCH

SEE MANUAL

OI/LMS100

!

!

 

 

ATEX/IECEx Name Plate

 

 

1

2

3

4

A

B

C

D

1

2

3

4

A

B

C

D

The information contained herein is

proprietary to and considered a trade

secret of ABB Inc., and shall not be

reproduced, in whole or

in part, without the written authorization

of ABB Inc.

Lang.:

Prepared by:

Title:

Part No.:

Doc. Type:

Date:

Rev.:

Sheet:

Drawing No.:

Approved by:

PA/MP/LM

Resp.

K-TEK PRODUCTS

18321 SWAMP ROAD

PRAIRIEVILLE, LA. 70769 USA

EN

LMS100 ATEX/IECEx

NAMEPLATE DRAWING

Norman W Guidry

Eric Fauveau

         08/05/14

3KXL000391U0100 3KXL000391U0109

   -

ARTWORK DRAWING

       1 of 1

REV

DESCRIPTION

APPROVED

DATE

-

ECN0915

E.F.

-

CRITICAL / SCHEDULE DOCUMENT

NO MODIFICATION PERMITTED WITHOUT APPROVAL

FROM AGENCY / NOTIFIED BODY

.700 [17.8]

4.00 [101.6]

SUBSTRATE LAYER

ADHESIVE LAYER

ADHESIVE LAYER

OVERLAMINATE LAYER

3KXL000391U0100 LAYERS

3KXL000460U0100

3KXL000461U0100

PRO

DE

3KXl

!

L

NOTES:
1. LABEL MATERIAL:

   - SUBSTRATE LAYER: BRADY B-428
   - OVERLAMINATE LAYER: BRADY B-111
   - ADHESIVE LAYERS: HIGH PERFORMANCE ACRYLIC
2.  LABEL TEMP. RANGE: -40°C TO 150°C (OUTDOOR)
3.  LABEL MUST BE RESISTANT TO OCCASIONAL EXPOSURE TO

PETROLEUM SOLVENTS.

4.  REFER TO 3KXL000391U0018 FOR MARKING PROCEDURE.
5.  DIMENSIONS ARE IN INCHES [MM].

MADE IN USA

IP66/IP67

-40°C

T

A

70°C

II 2 G, Ex d IIC T6...T1 Gb
II 2 D, Ex tb IIIC T85°C...T450°C Db
FM14ATEX0029X, IECEx FMG 14.0015X
II 1 G, Ex ia IIC T6...T1 Ga
II 1 D, Ex ia IIIC T85°C...T450°C Da
FM14ATEX0030X, IECEx FMG 14.0015X
II 3 G, Ex nC IIC T6...T1 Gc
FM14ATEX0031X, IECEx FMG 14.0015X

SEE MANUAL

OI/LMS100

!

!

LMS100.XX.XX.XX.XX
SN: 3K650000000000
MAGNETIC SWITCH

0575

250V MAX

1A MAX

60VA MAX

(NON-IS/NI)

K-TEK PRODUCTS

MADE IN USA

IP66/IP67

-40°C

T

A

70°C

II 2 G, Ex d IIC T6...T1 Gb
II 2 D, Ex tb IIIC T85°C...T450°C Db
FM14ATEX0029X, IECEx FMG 14.0015X
II 1 G, Ex ia IIC T6...T1 Ga
II 1 D, Ex ia IIIC T85°C...T450°C Da
FM14ATEX0030X, IECEx FMG 14.0015X
II 3 G, Ex nC IIC T6...T1 Gc
FM14ATEX0031X, IECEx FMG 14.0015X

SEE MANUAL

OI/LMS100

!

!

LMS100.XX.XX.XX.XX

SN: 3K650000000000

MAGNETIC SWITCH

0575

250V MAX

1A MAX

60VA MAX

(NON-IS/NI)

K-TEK PRODUCTS

Summary of Contents for LMS100 Series

Page 1: ... Manual OI LMS100 EN Rev A KTEK products Measurement made easy Introduction The operation and instruction manual provides the following information Mounting and installation Service instructions Electrical installation drawing Installation and parts drawing ...

Page 2: ...ons 6 5 2 1 General Guidelines 6 5 2 2 Nameplate Marking Procedure Declaration of Protection Concept 6 5 2 3 Flameproof Explosion Proof Requirements 7 5 2 4 Protection by Enclosure Requirements 7 5 2 5 Inrinsic Safety Non Incendive Requirements 8 5 3 Typical Applications 9 5 4 Typical D C Applications 9 5 5 Typical A C Applications 9 6 0 Service 10 7 0 Replacement Parts 11 8 0 Datasheet Specificat...

Page 3: ...magnetic float travel ing relative to the LMS100 causes the reed switch to change state After the float has passed the reed switch will maintain its state until the float reverses direction and passes the switch in the opposite direction The action of the switch is break before make The hermetically sealed contacts serve to ensure a high degree of hazardous area safety weather resistance and gener...

Page 4: ... LMS100 LO LEVEL SWITCH LMS100 HI LEVEL SWITCH KM26 Chamber Rod Mount LMS100 Rod Mounting Hardware Swivel Mounting Bolts LMS100 Switch Note 1 KM26 chambers that are furnished with factory in stalled insulation blankets may have switches mounted via special rod mount brackets to a factory installed switch mount rod that is external to the insulation See section 4 2 2 When mounting adjusting rod mou...

Page 5: ...e sure Circuit is de energized prior to Installing the switch If INstalling in a hazadous location Read requirements in 5 2 before proceeding 1 To remove the cover first unlock the cover security bolt located at the 5 o clock position of the cover by turning it clockwise with an M2 5 hex key When the bolt head no longer touches the cover grip the cover tightly and rotate it counterclockwise to rem...

Page 6: ...KXL130100G0022 CONDUIT SEAL REQUIRED WITHIN 2 IN SCELLEMENT EXIGE SUR CONDUIT A 50 MM 40 C TA 70 C CLII DIV2 GP EFGT6 CLIIIT6 CLI Zn2 AEx nC IIC T6 T1 Ex nC IIC T6 T1 Gc NI CLI DIV2 GP ABCDT6 CLII GP EFG T6 CLIIIT6 CLI Zn1 AEx d IIC T6 T1 Ex d IIC T6 T1 Gb Zn21AExtbIIICT85 C T450 C XP CLI GP ABCD T6 CLII GP EFG T6 CLIIIT6 CLI Zn0 AEx iaIICT6 T1 Ex ia IIC T6 T1 Ga Zn20AExiaIIICT85 C T450 C IS CLI G...

Page 7: ...rature class Maximum Process Temperature Temperature Class 40 F 40 C T 167 F 75 C T6 167 F 75 C T 194 F 90 C T5 194 F 90 C T 257 F 125 C T4 257 F 125 C T 374 F 190 C T3 374 F 190 C T 554 F 290 C T2 554 F 290 C T 780 F 416 C T1 5 2 4 Protection by Enclosure Installation Requirements Ex tb Field wiring fittings such as cable glands and conduit must main tain the ingress protection rating of the encl...

Page 8: ...USED SWITCH CONTACTS MUST BE ELECTRICALLY ISOLATED 5 IN USE I S SWITCH CONTACTS MUST SHARE THE SAME SAFETY BARRIER CHANNEL 6 VOLTAGE APPLIED TO OR SUPPLIED BY ASSOCIATED APPARATUS MUST NOT EXCEED 250 V 7 PARALLEL OR SERIES OF COMBINATION OF SAFETY BARRIER OUTPUT TERMINALS IS NOT PERMITTED 8 WARNING SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR USE IN HAZARDOUS LOCATIONS AVERTISSEMENT LA SU...

Page 9: ...induced voltage of the inductive load to as safe level NOTE Not evaluated for use in hazardous locations 5 5 Typical A C Applications For A C applications a Metal Oxide Varistor MOV transient surge suppressor is placed either in parallel with the switch or the inductive load The MOV changes from a high impedance to a very low impedance when the voltage across the MOV exceeds its rated voltage the ...

Page 10: ...ason then make sure the circuit is de energized or that the area is known to be non hazardous The LMS100 s reed switch core assembly is field replace able In the event of a failure a replacement can be ordered through an ABB sales representative by referencing part number 3KXL130100L0001 Reed Switch Core Assembly Replacement Instructions CAUTION De energize all field wiring before servicing 1 To r...

Page 11: ...ergized before proceeding 5 Insert the terminal plug and reconnect any field wiring removed in step 2 Replace the cover and tighten fully Be sure to lock the cover in place by turning the cover security bolt counterclockwise with an M2 5 hex key until the bolt is pressed firmly against the cover 7 0 Replacement Parts ...

Page 12: ... T6 T1 Ga CLII GP EFG T6 CLIII T6 Zn20 AEx ia IIIC T85 C T450 C XP CLI GP ABCD T6 CLI Zn1 AEx d IIC T6 T1 Ex d IIC T6 T1 Gb CLII GP EFG T6 CLIII T6 Zn21 AEx tb IIIC T85 C T450 C NI CLI DIV2 GP ABCD T6 CLI Zn2 AEx nC IIC T6 T1 Ex nC IIC T6 T1 Gc CLII DIV2 GP EFG T6 CLIII ATEX IECEx 40 C TA 70 C II 1 G Ex ia IIC T6 T1 Ga II 1 D Ex ia IIIC T85 C T450 C Da II 2 G Ex d IIC T6 T1 Gb II 2 D Ex tb IIIC T8...

Page 13: ...l bond A magnetic float traveling in a chamber relative to the LMS100 causes the reed switch to change state After the float has passed the reed switch will maintain it s state until the float reverses direction and passes the switch in the opposite direction The action of the switch is break before make The hermetically sealed contacts serve to insure a high degree of hazardous area safety weathe...

Page 14: ... arose only under normal use and service and which were not the result of either alterations misuse abuse improper or inadequate adjust ments applications or servicing of the product ABB s warranty does not include onsite repair or services Field service rates can be supplied on request If a product is believed to be defective the original purchaser shall notify ABB and request a Returned Material...

Page 15: ...ial Safety Data Sheets MSDS and decontamination tags by affixing these documents in close proximity to the shipment label for identification purposes January 18 2006 Return Authorization Form Customer Date Contact Name Product Contact Email Serial No Contact Phone Job No Contact Fax Service Rep Completed by Customer Reason Problem Found None Action None Requested Is expedited return shipping reque...

Page 16: ...ola li cn abb com ABB Limited Salterbeck Trading Estate Workington Cumbria England CA14 5DS Phone 44 7885333752 Service 44 145 3826661 E mail enquiries mp uk gb abb com Service e mail abb service gb abb com www abb com level Note We reserve the right to make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall pr...

Reviews: