To configure the new board:
1. Connect the laptop directly to the electronic board using the correct cable and
adapters for the board.
2. Start the MasterLink version 2.0 software.
3. Click the Comm. Port drop down list.
4. Select the laptop communication port used.
1. Leave Baud Rate at 9600 (factory default).
2. Click
Setup LevelMaster
.
3. Select
I have only one LevelMaster connected to communication port and I
want to set it up
.
4. Click
Setup
LevelMaster
.
5. Observe the messages displayed on the monitor screen. Verify that the
communication is successful. The screen should indicate the number of tries
and 100% success.
6. When prompted to add the LevelMaster to the list, click
No
. The unit can be
added later.
7. If using the existing configuration, proceed to section 4.5.2,
Configure the new
electronic board with the existing configuration
.
8. If using a default configuration file, proceed to section 4.5.3,
Configure the new
electronic board with a default configuration
.
4.5.2 Configure the new electronic board with the existing configuration
Use this procedure if configuring the new board with the existing configuration file
saved in section 4.3.3,
Save the configuration
.
In this procedure the existing configuration is downloaded to the new board. The ID,
baud rate, and calibration data from the previous board are saved in the unit. The
float configuration must be changed to reflect the batteryless floats.
To download the existing configuration:
1. Select
the
Upload/Download
tab.
2. Under Send data to the LevelMaster from the file, click the browse (
[…]
) button.
3. At the browser, navigate to the folder where the existing configuration file was
saved (for example, C:\Program Files (x86)\ABB\MasterLink).
4. Locate and select the configuration file.
5. Click
Open
.
6. Click
Download Data to LevelMaster
.
7. Click
OK
when download is complete.
8. Click
the
Setup
tab.
9. Under Make Hardware change, click
Hardware change
.
10. In the Select category drop down list, select Float Configuration.
11. Click
Next
.
12. Select Float mode Dual Batteryless.
13. Click
Next
.
14. Click
Next
again to confirm that the float configuration will be changed.
15. Click
OK
when configuration change is complete.