4 Repair
4.4.3. Replacement of complete wrist unit, IRB 6640ID
259
3HAC026876-001 Revision: C
© Copyri
ght
200
6-2008 ABB.
All rights reserved.
3.
CAUTION!
The complete wrist unit weighs 187 kg! All lifting
equipment used must be sized accordingly!
4. Attach the lifting slings to the wrist unit and lift it to the
upper arm tube.
5. Insert the cabling and connectors through the wrist
unit and match the wrist against the upper arm tube
with guidance from the guide pins.
6. Secure the wrist unit with 10 of the 12 attachment
screws and washers.
wrist unit on page 257Location of
wrist unit on page 257
12 pcs; M12 x 50, 12.9 quality
UNBRAKO. Tightening torque:
115 Nm.
Reused screws may be used,
providing they are lubricated as
detailed in section
before fitting.
7. Remove the guide pins and secure the two remaining
attachment screws as detailed above.
8. Reconnect the motor connectors to the motors, axes
5 and 6. Fasten the cabling as shown in the cable
layout in the figure
Cable layout, wrist unit on page
.
9. Recalibrate the robot.
Calibration is detailed in a
separate calibration manual,
enclosed with the calibration
tools.
General calibration information
is included in section
Calibration
information
.
10. Refit any equipment previously removed from the
turning disk.
11.
DANGER!
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in section
cause injury or damage! on page 33
Action
Note
Continued