Operation Manual / TPL69-A10 / -A30 ... TPL77-A10 / -A30
8 Disassembly and assembly / 8.8 Dismantling and fitting nozzle ring
at turbine end
© Copyright 2020 . All rights reserved.
HZTL2481_EN
Rev.D
March 2020
Segment connection disassembly
Fig. 2
u
Loosen screws (61044) and remove segments (51012).
u
Fit two studs (90177) in the bottom section.
u
Pull gas inlet casing (51001) together with nozzle ring (56001) away
from gas outlet casing (61001) until the nozzle ring can be lifted out.
u
Fully withdraw the gas inlet casing and remove it.
CAUTION
Use suitable underlays when putting down gas inlet casing.
1) If present
u
Remove gasket (61050).
Page
108
/
134