Possible causes
Remedy
Low-pressure
or
high-pressure
stage
Axial clearance of the rotor excessive Contact ABB Turbocharging Service
Station
Table 19: Malfunctions during operation – Lubricating oil pressure too low
Drop in low-pressure stage speed
Possible causes
Remedy
Engine
Defects on the connected cylinders Contact enginebuilder
Low-pressure
stage
Heavy contamination of the tur-
bine
Clean
Damaged rotor components or
bearing
Contact ABB Turbocharging Service
Station
Change of operating state of high-
pressure stage
Check the operating point of the high-
pressure stage.
Pipes
Defects, such as leaks, in the ex-
haust gas pipes or charge air ducts
Repair
Table 20: Malfunctions during operation – Power2 LP speed reductions
Drop in high-pressure stage speed
Possible causes
Remedy
Engine
Defects on the connected cylinders
Contact enginebuilder
High-pressure
stage
Heavy contamination of the turbine
Clean
Damaged rotor components or bear-
ing
Contact ABB Turbocharging Service
Station
Change of operating state of low-
pressure stage
Check the operating point of the low-
pressure stage.
Pipes
Defects, such as leaks, in the exhaust
gas pipes or charge air ducts
Repair
Table 21: Malfunctions during operation – Power2 HP speed reductions
Increase in low-pressure stage speed
Possible causes
Remedy
Low-pressure
stage
Heavy contamination of the nozzle
ring
Contact ABB Turbocharging Service
Station
Table 22: Malfunctions during operation – Power2 LP speed increases
Increase in high-pressure stage speed
Possible causes
Remedy
High-pressure
stage
Heavy contamination of the nozzle
ring
Contact ABB Turbocharging Service
Station
Low-pressure stage defective
Contact ABB Turbocharging Service
Station
Pipes
Leak in exhaust gas pipe before the
low-pressure stage
Repair
Table 23: Malfunctions during operation – Power2 HP speed increases
Page