Operation Manual / A150-M56/66/57/67 - A155-M..
7 Periodic maintenance work / 7.5 Changing the absorption element
© Copyright 2021 ABB. All rights reserved.
HZTL4032_EN
Rev.Q
January 2021
Installing the absorption element
Fig. 36: Installing the absorption element
Product
81152 [Nm]
81154 [Nm]
A155-M
50
10
Table 18: Tightening torque (81152 / 81154)
1. Fit the new absorption element (81148) and flanges (81145 / 81146) with roll pins (81151)
and socket screws (81154).
Tighten socket screws (81154) crosswise. Observe the tightening torque.
2. Check value X = 15 mm +/- 0.1 mm along the circumference at four points (0°, 90°, 180°
and 270°).
If value X is not satisfied, unscrew the socket screws (81154) and repeat step one.
3. Fit the mounting plate (81149) with washers (81153) and hexagon-head screws (81152).
Observe the tightening torque.
4. Remove the filter silencer
(see Fig. 82: Installing the uncoupled filter silencer (see
Table 55: Tightening torque (72054)
.
Page
77
/
194
Summary of Contents for HT604364
Page 2: ......