Operation Manual / TPL67-C.. - TPL71-C..
5 Maintenance / 5.2 Cleaning the filter silencer
© Copyright 2020 . All rights reserved.
HZTL2488_EN
Rev.G
March 2020
Removing and cleaning filter silencer
If provided
u
Remove filter strip (81265).
u
Rinse filter strip (81265) using water with detergent additive or, if very
dirty, soak it and squeeze out carefully. Rinse it in cold water. Avoid
rough treatment (not a jet of water).
NOTICE
How dirty the filter strip (81265) is, depends on how clean the drawn-in
air is. Clean filter strip every 500 hours of service or more frequently if
necessary.
u
Unscrew and remove lock nuts (81273).
u
Unscrew and remove screws (81272) for connecting rods (81269).
u
Remove connecting rods (81269).
u
Carefully remove cover grids (81266).
u
Pull out insert units (E), bend open sheet-metal coverings (81137) and
then remove absorption segments (81136).
u
Clean absorption segments (81136).
When cleaning, make sure that the absorption segments (81136) are
only cleaned lightly with pressurized air, a soft brush or with moist
cleaning cloths. Otherwise there is a risk of damage or deformation.
NOTICE
Replace heavily contaminated or damaged parts with original parts
from ABB.
Page
48
/
125