Operation Manual / TPS44-F.. - TPS61-F..
5 Maintenance / 5.4 Cleaning components mechanically
© Copyright 2020 . All rights reserved.
HZTL2412_EN
Rev.G
March 2020
5.4.4
Turbine-end, non-rotating parts
WARNING
Handling operating materials and supplies
Swallowing or inhaling vapours of operating materials and supplies or
contact with them may be harmful to health.
u
Do not breathe in these substances and avoid contact with the skin.
u
Ensure proper ventilation.
u
Observe the information in the material safety data sheet for the op-
erating materials and supplies.
u
Wear personal protective equipment (PPE) according to the material
safety data sheet.
u
Comply with local legislation.
Wear safety goggles.
Wear safety gloves to protect against chemical hazards.
Wear a respiratory mask to protect against gases.
Baked-on layers of contamination, for example from heavy fuel oil or
coked oil, occur at the turbine end. The following performance-relevant
parts can be cleaned according to the following description.
51000
Turbine casing
56001
Nozzle ring
52400
Gas outlet flange
u
Place contaminated parts in hot water or in a liquid such as brake
cleaner, so that the contamination softens.
u
Brush off the contamination or remove it with a steam cleaner.
u
Repeat the soaking and brushing if necessary.
u
Completely remove any solvents from the parts in clean water.
u
Dry components completely.
u
Spray cleaned surfaces with penetrating oil. Do not spray the outer
surfaces of the turbocharger.
u
Dispose of contaminated water and cleaning agent in accordance
with the specifications in the safety data sheet.
Page
60
/
113