Operation Manual / TPS44-F.. - TPS61-F..
5 Maintenance / 5.3 Turbine cleaning during operation
© Copyright 2020 . All rights reserved.
HZTL2412_EN
Rev.G
March 2020
Characteristic / com-
ponent
Conditions
short
Water injection time
long
Water injection time
Water supply
ensured
Water pressure (overpres-
sure over atmosphere) p
WT
2.0 bar
1.5 bar
If necessary, engine performance must be reduced to maintain these
conditions.
The cleaning cycle can now be started based on the following descrip-
tion.
Page
53
/
113