Operation Manual / 4 Product description / A150-M56/66/57/67 -
A155-M..
8 Dismantling and fitting, general / 8.1 Introduction
© Copyright 2019 ABB. All rights reserved.
HZTL4032_EN
Rev.N
October 2019
Press-off screws to be used
Six press-off screws (01) are required to press off the gas outlet flange, which are not sup-
plied by ABB Turbo Systems.
Fig. 32: Press-off screws
Product
Thread
Length
Quantity
A150
M12
30 mm
3 or 6
A155
M16
30 mm
3 or 6
Table 35: Press-off screws
Dismantling screw to be used for the optional 6-nozzle turbine cleaning component
A dismantling screw (01) is required to dismantle and fit the cleaning nozzles, which is not
supplied by ABB Turbo Systems
Fig. 33: Dismantling screw
Product
Thread
Length [mm]
Quantity
A150-M
M8
40
1
A155-M
M10
50
1
Table 36: Dismantling screw
Page
69
/
169