Operation Manual / 4 Product description / A100-M axial
7
Troubleshooting
Page 51 / 113
© Copyright 2016 ABB. All rights reserved.
HZTL4033_EN
Revision A
July 2016
7
Troubleshooting
7.1
Malfunctions when starting
Delayed start-up
Possible causes
Remedy
Turbocharger Turbocharger contaminated
Clean (
Bearing damaged
Contact ABB Turbocharging Service Station
Rotor rubbing
Foreign object in the turbocharger
Table 14: Malfunctions when starting – Delayed start-up
Vibrations
Possible causes
Remedy
Engine
Vibrations from engine
Contact enginebuilder
Turbocharger Rotor unbalance
Contact ABB Turbocharging Service Station
Turbine or compressor damaged
Bearing damaged
Table 15: Malfunctions when starting – Vibrations
Rubbing of rotating parts
Normal behaviour, not a malfunction
Turbocharger A minimal and uniform wear at the circumference of the rotor components caused by
slight local rubbing against adjacent components is permitted. This causes the com-
pressor or turbine blades to be somewhat shortened. To prevent significant loss of effi-
ciency, specific tolerances must be fulfilled.
If there is any doubt about the extent of the rubbing, contact an ABB Turbocharging
Service Station.
Have a dimension check carried out by an ABB Turbocharging Service Station.
Table 16: Malfunctions when starting – Rubbing of rotating parts