6.4.2
Wet cleaning of compressor
Figure 17: Overview of wet cleaning of compressor
81000
Filter silencer
A
Can
81126
Lock
B
Filler opening
Wet cleaning of compressor
Remove insulation at the flange of the filter silencer (81000) (if present).
Unscrew lock (81126).
Measure volume of water according to the following table.
Fill this water into a clean can (A).
Carefully pour this water into the filling orifice (B) with the can.
Screw in lock and hand-tighten.
Fit insulation on the flange of the filter silencer (if present).
After cleaning, allow the engine to continue to run for at least 5 minutes under normal load.
Repeating the cleaning
If the cleaning is still unsuccessful after three processes, it is recommended to have the turbo-
charger checked and cleaned by an ABB Turbocharging Service Station if the engine values
are unsatisfactory.