5.2.5
Service work according to instructions of enginebuilder
Clean or replace the oil filter located in the supply pipe to the turbocharger while the en-
gine is stopped.
5.2.6
Entries in the engine logbook
The monitoring of the engine system enables conclusions to be drawn on the behaviour of the
turbocharger.
The following operating data and measured values must be entered regularly into the engine
logbook of the enginebuilder:
Performance and speed of the engine
Speed of the turbocharger
Air intake temperature
Exhaust gas temperature before and after the turbine
Pressure of the charge air
Pressure loss in the charge air cooler
Lubricating oil pressure and lubricating oil temperature
Pressure loss in the filter silencer
Air temperature after the charge air cooler
If present:
Air temperature after the compressor