Operation Manual / 4 Product description / A130-M.. - A145-M..
8
Dismantling and fitting
Page 80 / 115
© Copyright 2015 ABB. All rights reserved.
HZTL4031_EN
Revision C
February 2016
8.5
Removing the gas outlet flange
NOTICE
Marking casing position for assembly
ABB Turbo Systems recommends marking the casing positions prior to
disassembly.
Figure 31: Removing the gas outlet flange
Product
Press-off screws to be used (strength 8.8)*
A130
6x M6
A135
6x M8
A140
6x M10
A145
6x M12
Table 36: Gas outlet flange press-off screws
*Not included in the ABB Turbo Systems scope of delivery.
1. Press off and remove the gas outlet flange (57002) with screws (S) according to the table.