2CDC172114M0201
11
2019-09-06
V1.3
Signal LED
The high-intensity LEDs are installed in the housing in such a way that they can easily be
perceived even in the normal ambient light in the workplace.
The controls are user-defined and can be controlled in a user-defined way via the AS-i
Bus.
Home position detector
A sensor, which can be implemented in the housing of the enabling device can recognize when the enabling
device has been hung-up in the specially-designed holder. (This holder is available as an accessory).
The signal from the sensor is transmitted via the AS-i Bus.
Attention!
This signal is not failsafe and shall never be used for safety purposes.
Assist light
(flashlight)
This function acts as an assist light to illuminate work spaces for short periods in which the
ambient light is not sufficient.
The controls are user-defined and can be controlled in a user-defined way via the AS-i Bus.
When using these, you must comply with the following:
Notice on duty cycle
•
On time = 60%, max. 15 min., ambient temperature
≤
35°C
•
On time = 40%, max. 10 min., ambient temperature > 35°C
•
Calculation
o
On-time percentage = (on time/on time + off time) x 100
o
On time = (D%/100- D%) x off time
o
Off time = (100-D%/D%) x duty cycle
Caution!
Increased heat build-up
Compliance with the requirements is absolutely vital, due to the additional heat generated by the assist
light!
If the specified limits are exceeded, the possibility that the AS-i electronics may be damaged cannot be
ruled out.
Attention!
Hazards arising from glare
Avoid looking directly into the lens of the assist light. Looking directly into the lens, and the glare effect
which may result from this, can sometimes impair vision, which may cause irritation, adverse effects, or
even accidents.