After power-on, the communicator performs a self-test. Then the communication to the
connected TZID-C/TZID-C200 is set up automatically, and the Online Menu seen below
is displayed:

The Online Menu provides five menu options:

Serve/ Watch
for display of several operating parameters

Settings
for setting the TZID-C/TZID-C200 parameters

Diagnostics
at present only providing an option for resetting the stroke and travel counters

Simulation
for simulating situations

Information
for entering/displaying device information 

There are two ways to select a menu. You can either enter the number of the menu item
via the alphanumeric keypad or mark the option with the 

 key and then select it with the

 key. 

Pressing the 

 or 

 (HOME) key will return you to the main menu. 

If the TZID-C/TZID-C200, with which you try to communicate via the HART

®

 communi-

cator has already been set locally to the Conf mode, the following message will pop up:
"Local configuration is active occurred reading ... value. Press OK."

In this case it is not possible to configure the positioner via the communicator. If you 
should ignore the message and nevertheless try to transmit data, the following message 
is shown:
"Access restricted".

If you try to read parameters from the TZID-C/TZID-C200 which are currently being 
modified locally, the input values are shown, even if they have not yet been confirmed 
and stored in the TZID-C/TZID-C200 EEPROM. It is recommended to cancel communi-
cation from the communicator and retry at a later time. 

TZID-C: -/-
Online

1 ->

2
3
4
5

Serve/Watch

Settings
Diagnostics
Simulation
Information

F3

Summary of Contents for HART HHT 275

Page 1: ...Simulation Information TZID C Online 1 2 3 4 5 Serve Watch Settings Diagnostics Simulation Information TZID C Online 1 2 3 4 5 Serve Watch Settings Diagnostics Simulation Information TZID C Online 1 2 3 4 5 Serve Watch Settings Diagnostics Simulation Information TZID C Online 1 2 3 4 5 Serve Watch Settings Diagnostics Simulation Information ...

Page 2: ...ls using the HART Protocol It provides a local operating option which adds up to direct local opera tion via the TZID C TZID C200 front panel and remote configuration by using the appro priate configuration program on a PC 2 Connection Connect the communicator to the positioner using the cable with 4 mm plug delivered with it The connection is made in parallel to the positioner s connection termin...

Page 3: ...see list below ABORT BACK DEL ENTER ESC EXIT HELP HOME NEXT NO OK PGDN PGUP PREV SEND YES Abort current function Return to current function Delete character right of cursor Accept user entered data Leave function ignore changes Exit menu return to prev level Call up context sensitive help Return to main menu Call up next display Negative answer to yes no question Acknowledge displayed message Page...

Page 4: ...key and then select it with the key Pressing the or HOME key will return you to the main menu If the TZID C TZID C200 with which you try to communicate via the HART communi cator has already been set locally to the Conf mode the following message will pop up Local configuration is active occurred reading value Press OK In this case it is not possible to configure the positioner via the communicato...

Page 5: ...al Auto configuration Analg pos feedback Dig pos feedb Options installed Valve range Min valve range Max valve range Digital setpoint Setpoint mode Travel setpoint Lever zero position Spring action actuator Control parameters kpUp kpDn tvUp tvDn Go pulse up Go pulse dn Offset up Offset down ADC noise Auto conf modes Auto conf locked Start auto conf Output min Output max Output action Alarm message...

Page 6: ...ke range 5 Shut off value Display the shut off value as a percentage of the stroke range 6 Temperature Display the temperature in C 7 Setpoint range 1 Lower current value Display the low setpoint range limit 2 Upper current value Display the high setpoint range limit 8 Operating mode Display the currently active operating mode as a plain text message F4 The following parameters cannot be called up...

Page 7: ...oner The parameters listed on the next pages can be edited via the communicator Select the digit to be changed with or selected digit flashes Press or to increase or decrease the flashing number You can also enter the new number via the numerical keys F3 F4 F4 The following parameters cannot be called up on the communicator Travel counter Travel counter limit Stroke counter Stroke counter limit Hy...

Page 8: ...nter a time limit for the dead band in seconds 6 Adjusted speed 1 Adjusted speed up Adjust the up travel speed in seconds 2 Adjusted speed dn Adjust the down travel speed in seconds 7 Alarmmask Enable disable the individual alarm messages e g Leakage towards actuator Press the key to toggle i e to enable or disable the respective alarm 8 Characteristic curve Select the characteristic curve to be u...

Page 9: ...erating mode when a voltage 12 V is applied to the dig ital input Please refer to the manual for the TZID C positioner 42 18 64 EN or for the TZID C200 positioner respectively 42 18 73 EN for a detailed descrip tion of the digital input functions AlarmOn active low OFF alarm output HIGH active ON alarm output LOW active S_1ON active low OFF switching point 1 HIGH active ON switching point 1 LOW ac...

Page 10: ... Travel setpoint This item is used to define the digital setpoint as a percentage Note that this setting can only be activated when the TZID C TZID C200 is currently work ing in mode 1 0 or 1 1 Otherwise an error message pops up 3 Lever zero position The lever zero position can be displayed edited with this menu item Options Stop turning clockwise Stop turning counterclockwise seen from the front ...

Page 11: ...ation is running is seen in the display After successful completion the message Auto configuration done appears You can either press OK to save the data in the TZID C TZID C200 s non volatile memory or press ABORT to reject the data Note that a running auto configuration can be stopped at any time by pressing ABORT 3 Options 1 Analg pos feedback 1 Output min Enter the current for 0 stroke travel T...

Page 12: ...s to toggle the reset option for the stroke counter and or travel counter between ON reset and OFF do not reset AlarmOn active low OFF alarm output HIGH active ON alarm output LOW active S_1ON active low OFF switching point 1 HIGH active ON switching point 1 LOW active S_2ON active low OFF switching point 2 HIGH active ON switching point 2 LOW active S1ON act below Off switching output 1 active wh...

Page 13: ...te deactivate the respec tive function 9 Information menu 1 Device Tag 1 Message Enter the device tag 2 Tag Enter the address on the bus 3 Description Enter the plant description 4 Measuring task Enter the measuring task 5 Date Enter the date format MMDDYY 2 HART 1 Universal rev Display the HART universal revision 2 Fld dev rev Display the field device revision 3 Num req preams Display the preambl...

Page 14: ...inear or rotary actuator 10 Troubles and Errors If the communicator cannot set up the communication with the positioner the message No device found is displayed Check the connection cables to the device and acknowledge the message with OK Restart communication setup by selecting the Online option from the displayed menu If the communicator displays the message Device busy while attempting to trans...

Page 15: ...ocopying and disseminat ing it in any form whatsoever even editings or excerpts thereof especially as reprint photome chanical or electronic reproduction or storage on data processing systems or networks is not allowed without the permission of the copyright owner and non compliance will lead to both civil and criminal prosecution Subject to technical changes Printed in the Fed Rep of Germany 42 1...

Reviews: