Turn on a light

If the outdoor station is configured by the indoor station, we can press the pushbutton to switch
on the light connected to the IP actuator. Please refer to the product manual for the IP touch.

Summary of Contents for H81381P Series

Page 1: ...2TMD041800D0010 07 12 2020 Product manual ABB Welcome IP H81381P IP pushbutton outdoor station ...

Page 2: ...the electrician 12 7 2 Mounting 13 7 2 1 Preparation 13 7 2 2 Installation height 13 7 2 3 Surface mounted installation 15 7 2 4 Flush mounted installation 16 7 2 5 Cavity wall installation 18 7 2 6 Dismantling 19 7 2 7 Replacing the nameplate 19 8 Commissioning 20 9 Operation 22 9 1 Call a resident 22 9 2 Call a guard unit 23 9 3 Turn on a light 24 10 Cyber security 25 10 1 Disclaimer 25 10 2 Per...

Page 3: ...Inhaltsverzeichnis Product manual 2TMD041800D0010 3 ...

Page 4: ...ep this manual in a safe place If you pass the device on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power...

Page 5: ...s a certificate issued by the management software before it can function normally Compatible mode If there is no management software this outdoor station needs to run in Compatible mode to function normally This can be set on the indoor station Please refer to the product manual for IP touch 7 Video privacy Video privacy Making and saving video recordings can infringe on personal rights Always obs...

Page 6: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Page 7: ...e Article number Product ID Product name Colour Size HxWxD Unit mm H81381P1 S 2TMA130010X0001 OS IPpush 1 gang Stainless steel 135 x 277 x 29 H81381P2 S 2TMA130010X0002 OS IPpush 2 gang Stainless steel 135 x 277 x 29 H81381P3 S 2TMA130010X0003 OS IPpush 3 gang Stainless steel 135 x 277 x 29 ...

Page 8: ...Product description Product manual 2TMD041800D0010 8 5 2 Control elements No Function 1 Camera 2 Speaker and microphone integration 3 Round pushbutton 4 End strip 1 2 3 4 ...

Page 9: ...DC GND for standalone power supply 4 Plug in clamps LOCK GND for door opener 5 Plug in clamps COM NC NO for floating output door opener 6 LAN PoE 7 Connector for next module 8 Connector for exit button 9 Connector for the sensor used for door status detection 10 Connector for 5 display module 11 Connector for previous module 7 11 1 2 3 4 5 6 7 8 9 10 ...

Page 10: ...ke lock 12V Power on to open 12 V Type A B Electrical strike lock 24V Power on to open 24 V Type B Electrical rim lock 12 V Power on to open 12 V Type A B Electrical mortise lock Power off to open 12 V Type C Magnetic lock Power off to open 12 24 V Type C GND NO DC NC LOCK COM GND NO DC NC LOCK COM GND NO DC NC LOCK COM PS PS Type A Type B Type C ...

Page 11: ...erature 40 C 55 C Product dimensions 135mm x 276 9 mm 17 6 mm Camera type CMOS Camera viewing angle 130 Resolution ratio HD 1280 x 720 pixel Power supply for door opener 18 V 4 A impulse max 250 mA holding Floating output for door opener 230 V AC 3 A 30 V DC 3 A Video codec H 264 Audio codec G 711 IP level IP 54 IK level IK 07 Network connection standard IEEE 802 3 10Base T 100Base TX auto MDI MDI...

Page 12: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Page 13: ...Mounting Installation Product manual 2TMD041800D0010 13 7 2 Mounting 7 2 1 Preparation Use gloves to protect yourself against cuts 7 2 2 Installation height 1 5 m 5 feet ...

Page 14: ...Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station Lamps or direct light sources ...

Page 15: ...Mounting Installation Product manual 2TMD041800D0010 15 7 2 3 Surface mounted installation 3 4 5 6 7 8 2 1 32 mm 40 mm 71 mm 211 mm 1X3 ...

Page 16: ...Mounting Installation Product manual 2TMD041800D0010 16 7 2 4 Flush mounted installation 1 Flush mounted without pre installation box 2 1 3 117 mm 46 mm 264 m m 1X3 4 5 6 7 8 9 ...

Page 17: ...Mounting Installation Product manual 2TMD041800D0010 17 2 Flush mounted with pre installation box 3 2 1 274 m m 126 m m 68 m m 1X3 10 5 6 7 8 9 4 ...

Page 18: ...Mounting Installation Product manual 2TMD041800D0010 18 7 2 5 Cavity wall installation 1 2 3 4 10 5 6 7 8 9 6 5 ...

Page 19: ...Mounting Installation Product manual 2TMD041800D0010 19 7 2 6 Dismantling 7 2 7 Replacing the nameplate 1 2 3 ...

Page 20: ...de Power on the outdoor station wait a while until all 3 LED indicators go out Hold the first button on the outdoor station for 10 s until all 3 LED indicators start to flash Tip The outdoor station will quit engineering mode after 5 minutes Step 2 Indoor station enters engineering mode On the extra screen on the indoor station click System to enter the settings screen ...

Page 21: ...ering settings enter the engineering password default is 345678 to enter the settings page Step3 Indoor station configures outdoor station On the Engineering settings screen click Outdoor station settings to configure the outdoor station Please refer to the product manual for the IP touch 7 ...

Page 22: ...Operation Product manual 2TMD041800D0010 22 9 Operation 9 1 Call a resident Press the button to start a call default and press again to restart the call ...

Page 23: ...l 2TMD041800D0010 23 9 2 Call a guard unit If the outdoor station has been configured via the indoor station we can press the pushbutton to call the designated guard unit Please refer to the product manual for the IP touch 7 ...

Page 24: ...TMD041800D0010 24 9 3 Turn on a light If the outdoor station is configured by the indoor station we can press the pushbutton to switch on the light connected to the IP actuator Please refer to the product manual for the IP touch ...

Page 25: ...r losses related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although ABB provides functionality testing on the products and updates that we release you should institute your own testing program for any product updates or other major system updates to include but not limited to code changes configuration file changes third party ...

Page 26: ...vice This will prevent sensitive data leak It is recommended to apply MAC filter and Rate limiter in the switch to prevent DOS attack 10 4 Upgrading Device supports firmware updates via management software a signature file will be used to verify the authentication and integrity of firmware 10 5 Backup Restore None 10 6 Malware prevention solution The H81381P device is not susceptible to malware be...

Page 27: ...ed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Page 28: ...is document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ABB Xiamen Smart Technology Co Ltd No 7 Fangshan South Road Hi tech area Torch park Xiang An District Xiamen China Tel 86 592 295 9000 Fax 86 592 562...