background image

Operation

Operating Instructions 2TMD041700D0043

21

Pos: 72 /CNDEX/01 Heading/1. Heading/Heading_Operation @ 56\mod_1487743450854_15.docx @ 749873 @ 1 @ 1

9

Operation

Pos: 73 /CNDEX/01 Heading/1.1 Heading/Heading_Manage ID cards_Mini OS @ 57\mod_1488184673779_15.docx @ 752213 @ 2 @ 1

M

9.1

Manage ID cards by mini outdoor station

Pos: 74 /CNDEX/09 Operation/Note_Manage ID cards_H8131xPx-A_H8136xPx-A_Mini OS @ 62\mod_1496626855073_15.docx @ 785237 @  @ 1

Note

Please assign mini outdoor station to a specific apartment first before
configuring ID card. And "Local card" is set ON.

Pos: 75 /CNDEX/09 Operation/Manage ID cards_M2131xPx-A_M2136xPx-A_Mini OS @ 56\mod_1487656695658_15.docx @ 748655 @  @ 1

Programming

Function

Command

Indicated color of door open

Create admin card

Swipe card 1x

Green

Enter settings

Swipe admin card 1x

Orange

Tab.5: 

Create admin card and enter settings

The system will take the first card swiped after powering up the system within 60s to be the

admin card.

After entering settings, following functionalities can be implemented:

Function

Command

Indicated color of door open

Enroll user

Swipe admin card 1x

Orange flash 1x

Swipe user card 1x

Green

Delete user

Swipe admin card 2x

Orange flash 2x

Swipe user card 1x

Green

Enroll new admin

Swipe admin card 3x

Orange flash 3x

Swipe new admin card 1x

Green

Delete admin

Swipe admin card 4x

Orange flash 4x

Swipe other admin card 1x

Green

Delete all users

Swipe admin card 5x

Orange flash quickly

Swipe admin card 1x

Green

Tab.6: 

Enroll and delete admin and user cards

During setting, please swipe the same admin card.

Function

Command

Indicated color of door open

Exit settings

Swipe admin card 1x or no
cards swiped within 15 seconds

--

Tab.7:  Exit 

setting

Summary of Contents for H8131xPx-A

Page 1: ...le 00_Title H8131xPx A_H8136xPx A 63 mod_1500619849797_0 docx 801103 1 2TMD041700D0043 01 08 2017 Operating Instructions ABB Welcome IP Mini video outdoor station H8131xPx A H8136xPx A Ende der Liste für Textmarke Titel ...

Page 2: ...ontrol elements 5 5 2 Feature 6 5 3 Terminal description 7 5 4 Lock type and connection 8 6 Technical data 9 7 Mounting Installation 10 7 1 Requirement for the electrician 10 7 2 Mounting 11 7 2 1 Surface mounted installation 12 7 2 2 Flush mounted installation 14 7 2 3 Cavity wall installation 16 7 2 4 Dismantling and replacing the nameplate 18 7 2 5 Installation situations 19 8 Commissioning 20 ...

Page 3: ...afety Pos 11 CNDEX 00 Warning Warning_Electric voltage_Dangerous currents 56 mod_1487741007782_15 docx 749637 1 Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power supply prior to installation and or disassembly Permit work on the 110 240 V...

Page 4: ...g_ABB devices 62 mod_1496803248336_15 docx 786222 2 1 4 1 ABB devices Pos 20 CNDEX 00 Warning Txt_ABB devices_Environment 56 mod_1487743585555_15 docx 749915 12 1 All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company...

Page 5: ... mod_1487747434664_15 docx 750030 2 1 5 1 Control elements Pos 25 CNDEX 03 Front overview Front overview_H8131xPx A_H8136xPx A_Mini OS 56 mod_1487644245434_15 docx 748007 1 Fig 1 Control elements No Function 1 Light sensor 2 Infrared LED 3 Indicator LED ring call and door open 4 Speaker and microphone integration 5 Pushbutton 6 Nameplate Tab 1 Description Pos 26 CNDEX 99 Auxiliary tools page break...

Page 6: ...with optional ID 125 KHz card reader The 2nd button if available can be programmed to call guard unit PC guard or another residence Supports 2 locks connection Supports door status detection Supports exit button to release the lock 0 3M pixel camera with large detection angle H 86 V 67 D 104 Anti fog design camera with in built heater In built lighting and automatic backlight ensure clear view at ...

Page 7: ...ector for exit pushbutton 3 Plug in clamps LOCK AGND for door opener 15V 4A impulsive 250 mA holding 4 Plug in clamps COM NC NO for floating output door opener 30 VAC DC 1A 5 Plug in clamps DC GND for standalone power supply 6 Connector for TCP IP RJ45 port 7 LED indicator of LAN port 8 Set feedback tones for pushbuttons when pressing and outdoor station during a call 9 Assigns default lock ie 12V...

Page 8: ... Electrical strike lock 24 V Power on to open 24 VDC AC Type B Electrical rim lock 12 V Power on to open 12 VDC Type A Type B Electrical mortise lock Power off to open 12 VDC Type C Magnetic lock Power off to open 12 24 V DC Type C Tab 3 Lock type Pos 35 CNDEX 05 Terminal description Lock connection_H8131xPx A_H8136xPx A_Mini OS 56 mod_1487648035242_15 docx 748091 1 Fig 3 Lock connection Pos 36 CN...

Page 9: ...9_15 docx 748111 1 Designation Value Operating temperature 40 C 70 C Protection dustproof and waterproof as IP 54 vandal proof as IK 07 Power supply door opener Lock GND 15 V 4 A impulsive 250 mA holding Floating supply door opener COM NC NO 30 VDC AC 1A Operating voltage 27 VDC Dimension Surface mounted 168 mm x 99 mm x 26 mm Flush mounted 180 mm x 105 mm x 43 mm Tab 4 Technical data Pos 40 CNDEX...

Page 10: ..._Electric voltage_Install the device 56 mod_1487743205578_15 docx 749810 1 Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledg...

Page 11: ...ing Pos 48 CNDEX 07 Mounting Installation Preparation_OS 56 mod_1487742936063_15 docx 749767 1 Use gloves to protect yourself from being cut Fig 4 Preparation Pos 49 CNDEX 07 Mounting Installation Wiring_H8131xPx A_H8136xPx A_Mini OS 56 mod_1487653746613_15 docx 748216 1 Fig 5 Wiring Pos 50 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 LAN ...

Page 12: ...od_1487748770156_15 docx 750153 2 1 7 2 1 Surface mounted installation Pos 52 CNDEX 07 Mounting Installation Surface mounted installation_H8131xPx A_Mini OS 56 mod_1487653889110_15 docx 748237 1 Fig 6 Product dimension Fig 7 Installation dimension Fig 8 Surface mounting on the wall 99 mm 26 mm 168 mm 78 mm 62 mm 6 0 m m 147 mm 83 mm 62 mm 1 2 ...

Page 13: ...Mounting Installation Operating Instructions 2TMD041700D0043 13 Fig 9 Surface mounting with standard flush mounted box Pos 53 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 1 2 ...

Page 14: ...1487748835312_15 docx 750174 3 1 7 2 2 Flush mounted installation Pos 55 CNDEX 07 Mounting Installation Flush mounted installation_M2136xPx A_Mini OS 56 mod_1487654436221_15 docx 748258 1 Fig 10 Product dimension Fig 11 Mounting without pre installation box 90 mm 105 mm Front view Back view Side view 180 mm 168 mm 43 mm 90 mm 168 mm 33 mm 10 mm ...

Page 15: ...installation box is highly recommended to ensure the efficient and sleek installation Without the pre installation box in case the hole is deeper or tilt the installation will looks ugly or hard to install For flush mounting in a cavity wall the pre installation box is not need Fig 13 Installation flexibility Pos 57 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 99 mm 99 ...

Page 16: ...d_1487748890973_15 docx 750195 3 1 7 2 3 Cavity wall installation Pos 59 CNDEX 07 Mounting Installation Cavity wall installation_H8136xPx A_Mini OS 56 mod_1487655095826_15 docx 748529 1 Fig 14 Product dimension Fig 15 Installation dimension 90 mm 105 mm Front view Back view Side view 180 mm 168 mm 43 mm 7 mm 29 mm 92 mm 97 mm 170 mm 120 mm ...

Page 17: ...o the back of outdoor station with 4 screws The direction of the claws please refer to the picture above Tie up 4 claws with 2 rubbers Put the back cover into the cavity wall Tighten 4 screws Latch the upper part onto the bottom part Pos 60 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 ...

Page 18: ...1833993640_15 docx 813237 3 1 7 2 4 Dismantling and replacing the nameplate Pos 62 CNDEX 07 Mounting Installation Dismantling and replace the nameplate_Mini OS_1A 64 mod_1501048797771_15 docx 806429 1 Fig 17 Dismantling Fig 18 Replace the nameplate Pos 63 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 in TT L N out TT L N 39 mm 35 mm ...

Page 19: ...X 00 Warning Note_Installation situations 56 mod_1487743694622_15 docx 749937 1 Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station Lamps or direct light sources Pos 66 CNDEX 99 Auxiliary tools page break 57 mod_148781473594...

Page 20: ...ing_Commissioning 57 mod_1487828936105_15 docx 751257 1 1 8 Commissioning Pos 69 CNDEX 08 Commissioning Find details in the system manual 62 mod_1497234325447_15 docx 788858 1 Please find details in the system manual Pos 70 CNDEX 99 Auxiliary tools page break 57 mod_1487814735946_0 docx 750979 1 ...

Page 21: ...card 1x Green Enter settings Swipe admin card 1x Orange Tab 5 Create admin card and enter settings The system will take the first card swiped after powering up the system within 60s to be the admin card After entering settings following functionalities can be implemented Function Command Indicated color of door open Enroll user Swipe admin card 1x Orange flash 1x Swipe user card 1x Green Delete us...

Page 22: ...o enter configuration mode Press and hold the 1st button for 10 s to reset to factory default Reboot the device 3 LED green cycle flash 3 LED OFF Door open LED red green orange cycle flash Tab 9 Reset to factory default Technical data of ID card Work frequency Standard Support ID card protocol 125KHz ISO18000 2 EM4100 EM4205 EM4305 EM4450 TK4100 T5567 T5577 Tab 10 Technical data of ID card Pos 76 ...

Page 23: ...es to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted o...

Page 24: ... P O Box 325841 Riyadh 11371 T 966 1 1484 5600 F 966 1 1206 7609 ABB Thailand Ltd 161 1 SG Tower 1st 4th Floor Soi Mahadlekluang 3 Rajdamri Road Lumpini Pathumwan Bangkok 10330 Thailand T 66 2 6651 000 F 66 2 6651 043 ABB Russia Ltd 3121 Wiring Accessories 30 1 bld 2 Obrucheva str RU T 7 495 777 2220 F 7 495 777 2220 ABB Korea Ltd Oksan Bldg 10th Fl 157 33 Samsung dong Gangnam gu 135 090 Seoul Kor...

Reviews: