Connection Diagram
ABB Instrumentation
WD-J-076-6
Rev 5
Sheet 1 of 1
76J Recorders with
1401, 1402, 1403, 1404 EME Elements
Cat. No.
Cust. No.
ABB No.
Also Refer to Dwgs.
Certified by
Date
Not for construction unless certified.
Printed in U.S.A. ©, 1998, ABB Instrumentation Inc.
Drawing applies only to the following Cat. Nos.:
Recorder: 76
J * T O O * * * * ** * C
T T
Element:
1401
L
A * ** ** * D
1402
1403
1404
* can be any digits
1401L EME
Input Terminals
NOTES:
1. Do not use wire larger than 16 ga for voltage, current or
resistance element input connections. 24 ga or 0.5 mm wire is
recommended for mV and thermocouple input connections and
must be a twisted shielded pair or a twisted pair in conduit.
2. Run all signal wires in same conduit to minimize temperature
effects.
3. L
– Hot (live) wire
– Ground (earth) wire
N
– Common (neutral) wire
1402L EME
Input Terminals
1404L EME
Input Terminals
Power Terminals
(View Below
Applies)
CHART DRIVE TYPE
Electric (General Purpose) 120V, 60Hz
Electric (General Purpose) 120V, 50Hz
Electric (General Purpose) 240V, 60Hz
Electric (General Purpose) 240V, 50Hz
Spring Wound, 9 Day wind
Spring Wound, 9 Day wind
Battery Operated
Input Signal
1401L
1402L
1404L
Resistance Element
4 to 20 mA dc
0.25 to 1.25V dc
0 to 1V dc
0 to 5V dc
Summary of Contents for Fulscope 76J Series Model C
Page 1: ...Fulscope 76J Series Model C Instructions Pneumatic Recorder ABB Instrumentation ...
Page 18: ...76J Pneumatic Fulscope Recorder OPERATION 14 Figure 7 Chart Plate and Chart Drive Components ...
Page 20: ...76J Pneumatic Fulscope Recorder OPERATION 16 ...
Page 34: ...76J Pneumatic Fulscope Recorder MAINTENANCE 30 ...
Page 39: ...76J Pneumatic Fulscope Recorder PARTS LIST 35 Figure 23 Two Pen Movement 93S115 ...
Page 40: ...76J Pneumatic Fulscope Recorder PARTS LIST 36 Figure 24 Three Pen Movement 93S99 ...
Page 52: ......