Maintenance 511
Factory reset
Do a factory reset if
• you forget the password
• you want to do the configuration again from scratch.
Note:
The factory reset clears the configuration and takes the factory default
values back in use. These factory default values are not the same as the pre-set
values in a delivered FSO (ordered with a plus code). The factory default values
are invalid for restart. The FSO needs a full reconfiguration before it can be
restarted. You can also use the safety file that was saved at the first start-up
(see page
1. Make sure that the motor is stopped.
2. Lift the Factory reset label on the right side of the I/O terminals. Push the button
underneath with, for example, a pen until the LEDs start to flash (approximately
5 seconds). This returns the factory settings (parameters, including the password)
to the FSO.
3. Reconfigure the safety functions with the Drive composer pro PC tool. To be able
to restart the drive, make sure that at least these parameters are set to suitable
values according to your application:
4. Set a new password with the tool.
Parameter
index
Name
Factory default
value
Pre-set value
(with option
+Q972)
Motor nominal speed
100.0 rpm
1500.0 rpm
Motor nominal frequency
1 Hz
50 Hz
Power-up acknowledgement
Manual
Automatic
STO acknowledgement
Manual
Automatic
Restart delay after STO
3,600,000 ms
2000 ms
Time to zero speed with STO and
modoff
3,600,000 ms
2000 ms
STO SBC usage
Delayed brake
None
SLS acknowledgement
Manual
Automatic
1
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...