![ABB FSO-21 User Manual Download Page 412](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728412.webp)
412 Parameters
0…3,600,000 ms
Time
STO.21 STO output
Sets the digital output that indicates the
status of the STO function in the drive.
Active when the STO circuit in the drive is
open.
Note
: In a cascade connection, this
indicates the activity of the STO function of
the FSO module.
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
DO X113:8
Single output X113:8
DO X113:9
Single output X113:9
DO X114:7
Single output X114:7
DO X114:8
Single output X114:8
DO X114:9
Single output X114:9
STO.22 STO completed
output
Sets the digital output that indicates the
completion of the STO function. See the
diagrams in section
page
.
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
DO X113:8
Single output X113:8
DO X113:9
Single output X113:9
DO X114:7
Single output X114:7
DO X114:8
Single output X114:8
DO X114:9
Single output X114:9
SBC
Parameters for the SBC function
SBC.01 SBC version
Shows the version of the SBC function.
Version 1
Version 1.
SBC.11 STO SBC usage
Sets how the mechanical brake (SBC) is
used together with the STO function.
Note
: This parameter is used also in the
SSE function when it is configured as
Immediate STO
(parameter
).
None
No brake
Index
Name/Value
Description
Factory
default
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...