![ABB FSO-12 User Manual Download Page 244](http://html.mh-extra.com/html/abb/fso-12/fso-12_user-manual_2726244.webp)
244 Configuration
How to configure SS1 with speed limit activated SBC, SBC before
STO
Note
: If you configure the SS1 with speed limit activated SBC, SBC before STO
function, this activates the same function in the SSE function (see section
configure SSE with speed limit activated SBC
on page
). This does not activate
the SBC in the STO function. If necessary, configure the SBC also in the STO
function (see section
on page
). See also the note on page
.
Example 1:
The figure below shows an example of the SS1-t function with speed
limit activated SBC, SBC before STO set-up:
• SS1 function activated (
Version 1
)
• SS1 with time monitored ramp (
SS1-t
)
• SAR1 emergency ramp (always with the SS1 function)
• security delay for activating the drive STO: 2000 ms
2000 ms
)
• automatic acknowledgement (
=
Automatic
)
• redundant emergency stop button connected to input
=
DI X113:1 & X114:1
)
• single output connected (
=
DO X114:9
)
• brake connected to redundant output, diagnostic pulses activated
DO X113:7 & X114:7
and
=
On
)
• speed limit activated brake in use, speed below which the brake and STO are
activated: 180.0 rpm (
180 rpm
)
• delay for activating STO after brake: -300 ms (only a negative delay is possible,
the SBC is activated before STO) (
=
-300 ms
)
Note
: The same SBC delay is used in the STO and SS1/SSE functions.
• delay for activating the brake after the SBC speed limit has been reached: 0 ms
SS1-r ramp zero speed delay for STO
0 ms,
not shown in the figure)
• delay to define the safety function as completed, that is, estimated time in which
the motor brakes to a stop from the maximum speed: 1200 ms (
1200 ms
)
• STO is activated if brake feedback fails (
=
STO
)
• brake feedback input connected to input
=
DI X113:2
)
• feedback input type NC (inverted state compared with the brake relay)
Mechanically linked NC contacts
).
• See also section
.
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...