Connection, installation / mounting
Product manual
2CKA000073B5466
│
19
5.5 Mounting
/
dismantling
■
The flush-mounted installation is made in a Ø 55 mm installation box according to DIN
49073 behind the push-button.
■
The device can be mounted in any position.
■
The adhesive label is to be removed and glued into the list (see system manual System
Access Point).
■
Wires not required are to be insulated.
■
The bus connection is established by means of the enclosed bus connection terminal.
■
The device is ready for operation after the bus voltage has been applied.
■
The description of the terminals is located on the housing.
■
Access to the device must be guaranteed for operation, testing, inspection, for maintenance
and repairs according to DIN VDE 0100-520.
5.6 Dismantling
Dismantling is carried out in the reverse order to mounting.