Note
Action
xx1300002542
Connect the wires to the emergency stop
button and tighten the holding screws.
CAUTION
The color code of the wires in the retractable
cable do not match the color coding of the
original. See the preceding table and figure.
•
Connect GN-11 and YE-12 on the first
emergency channel.
•
Connect WH-21 and BN-22 on the
second emergency channel.
1
Tighten the sealing ring of the emergency
stop button.
2
See position D in the figure.
Connect the main connector.
3
See position C in the figure.
Put the grounding clamp in position and
tighten the screw.
4
See position A in the figure.
Put the retractable cable in position and at-
tach the clamps and screws.
5
Adjust the length of the cable and put the
gasket into the slot.
6
See position B in the figure.
Safety the cable and wires with plastic straps.
7
See position E in the figure.
Connect the connector of the teach pendant
back cover.
8
Put the housing cover in place. Make sure
that no wires are squeezed.
9
Tighten the screws.
10
This step is mandatory.
CAUTION
Verify that the emergency stop button and
the three-position enabling device are work-
ing.
11
30
Product manual - FlexPendant Retractable Cable
3HAC048816-001 Revision: B
© Copyright 2015-2016 ABB. All rights reserved.
2 Installation
2.3 Connecting the cables
Continued
Summary of Contents for FlexPendant
Page 1: ...Product manual FlexPendant Retractable Cable ...
Page 6: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 42: ...This page is intentionally left blank ...
Page 44: ......
Page 45: ......