Protective stop
Protective stop is transmitted via a two-channel, potential free signal to the
connected system from the safety relay of the FlexLoader Standard Safety Center.
Optionally, the connected system transmits a protective stop via a two-channel ,
potential free signal to FlexLoader Standard Safety Center using a two channel
safety device. FlexLoader Standard Safety Center can be configured to accept a
dynamic signal instead.
FlexLoader Standard Safety Center is always the protective stop master.
The connected system is emergency stop master
Emergency stop is transmitted via a potential free, two-channel signal to the
connected system acting as an emergency stop button.
xx1800002553
Continues on next page
32
Application manual - FlexLoader Standard Safety Center
3HAC051769-001 Revision: E
© Copyright 2014-2020 ABB. All rights reserved.
5 Interface
5.1 External safety interface to connected system
Continued