background image

4  FEA-01 user’s manual        

FEA-01 F-series Extension Adapter

„

Overview

The FEA-01 F-series Extension Adapter is an extension unit for the 

mounting of FIO I/O extension modules and FEN encoder modules 

outside the drive unit. The FEA-01 is connected to the drive via a 

DDCS-protocol fiber-optic link. One I/O extension module can be 

mounted on one FEA-01 adapter. Several FEA-01 adapters can be 

connected in a ring topology using fibre optic cable.

„

Optical component types

The FEA-01 has a 10 MBd fiber-optic link. The drive must also 

have a 10 MBd DDCS fiber-optic connection. The following optical 

cable types can be used:

Note:

 The optical components (transmitter and receiver) on a fibre 

optic link must be of the same type.

Plastic optical fibre (POF) cables (max. length 30 m) and

Hard Clad Silica (HCS

®

) cables (max. length 200 m).

HCS cables allow longer connection distances because of their 

lower attenuation. HCS

®

 is a registered trademark of SpecTran 

Corporation.
The optical component types used in ABB drive equipment are 

presented in 

Settings and connections

.

A6 manual template.book  Page 4  Friday, January 8, 2010  3:39 PM

Summary of Contents for FEA-01 F Series

Page 1: ...ABB Drives User s manual FEA 01 F series Extension Adapter 3AUA0000071412 REV A Effective 2010 01 08 2010 ABB Oy All rights reserved A6 manual template book Page 1 Friday January 8 2010 3 39 PM ...

Page 2: ...A6 manual template book Page 2 Friday January 8 2010 3 39 PM ...

Page 3: ...nstall and maintain the drive The drive and adjoining equipment must be properly earthed Do not work on a powered drive After switching off the input power always allow the intermediate circuit capacitors 5 minutes to discharge before working on the drive the motor or the motor cable Always ensure by measuring with a multimeter impedance at least 1 Mohm that the drive is discharged before beginnin...

Page 4: ...onent types The FEA 01 has a 10 MBd fiber optic link The drive must also have a 10 MBd DDCS fiber optic connection The following optical cable types can be used Note The optical components transmitter and receiver on a fibre optic link must be of the same type Plastic optical fibre POF cables max length 30 m and Hard Clad Silica HCS cables max length 200 m HCS cables allow longer connection distan...

Page 5: ...such as the diagnostic LED fiber optic transmitter V1 receiver V2 and power supply connector Power supply The FEA 01 requires a supply voltage of 24 V DC 10 10 MBd channel 68 mm 2 7 in V1 V2 Power supply connector 24 V DIN rail mounting Diagnostic LED POWER OK 24 V DC GND 120 mm 4 7 in 67 mm 2 6 in F series module connector A6 manual template book Page 5 Friday January 8 2010 3 39 PM ...

Page 6: ...ion Connect the FEA 01 V1 TXD connector to the drive RXD connector Connect the FEA 01 V2 RXD connector to the drive TXD connector as shown below Multiple FEA 01 F series Extension Adapters are connected together in a ring topology as shown below For more information on the fiber optic link connection see the relevant firmware manual Drive FEA 01 FEA 01 FEA 01 V2 V1 V2 V1 V2 V1 RXD TXD Drive RXD TX...

Page 7: ...pper conductor may be used stranded wire allowed only The unit should be mounted so that air can freely pass through the ventilation holes in the housing Mounting directly above heat generating equipment should be avoided Mounting an I O extension module To mount an I O extension module insert the plastic retaining clips of the module a into the slots in the FEA 01 and fasten the screw b Correct i...

Page 8: ... optic link connection Avago Versatile Link 10 MBd Power supply connection Detachable screw terminal block Phoenix Contact MSTBA 2 5 2 G 5 08 LED Diagnostic LED labeled POWER OK Ambient conditions The applicable ambient conditions specified for the drive in its hardware manual are in effect Degree of protection IP20 Standards Complies with the safety standard IEC 61800 5 1 and EMC standard IEC 618...

Page 9: ... ABB product training navigate to www abb com drives and select Training courses Providing feedback on ABB Drives manuals Your comments on our manuals are welcome Go to www abb com drives and select Document Library Manuals feedback form LV AC drives Document library on the Internet You can find manuals and other product documents in PDF format on the Internet Go to www abb com drives and select D...

Page 10: ...015 Telephone 86 10 5821 7788 Fax 86 10 5821 7618 Internet http www abb com Contact us ABB Oy Drives P O Box 184 FI 00381 HELSINKI FINLAND Tel 358 10 22 11 Fax 358 10 22 22681 www abb com drives ABB Inc Automation Technologies Drives Motors 16250 West Glendale Drive New Berlin WI 53151 USA Tel 262 785 3200 1 800 HELP 365 Fax 262 780 5135 www abb com drives ABB Beijing Drive Systems Co Ltd No 1 Blo...

Reviews: