1  Introduction 

Scope 

The purpose of these instructions is to describe the emergency stop EStrong-series, and to provide the necessary 

information required for assembly, installation, operations, checks and adjustments after installation, and 

maintenance. The instructions also include information necessary to connect EStrong to a safety circuit. 

Audience 

This document is intended for authorized installation personnel. 

Prerequisites 

It is assumed that the reader of this document has knowledge of the following: 

  Basic knowledge of ABB Jokab Safety products. 

  Knowledge of machine safety. 

Special notes 

Pay attention to the following special notes in the document: 

 Warning!

 

Danger of severe personal injury! 
An instruction or procedure which, if not carried out correctly, may result in injury to the technician 

or other personnel. 

Caution!

 

Danger of damage to the equipment! 
An instruction or procedure which, if not carried out correctly, may damage the equipment. 

NB:  Notes are used to provide important or explanatory information. 

Summary of Contents for EStrong Series

Page 1: ...ABB AB Jokab Safety Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Original instructions EStrong series Emergency Stop...

Page 2: ...AFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete dete...

Page 3: ...tes 4 Special notes 4 2 Overview 5 General description 5 Safety regulations 5 Function description 5 3 Connections 6 4 Installation and maintenance 7 Installation and maintenance 7 Maintenance 7 5 App...

Page 4: ...or authorized installation personnel Prerequisites It is assumed that the reader of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safet...

Page 5: ...e instructions or standards especially when tampering with and or modifying the product any liability is excluded Function description The EStrongZ contact block configuration is a 2NC and 2NO and the...

Page 6: ...172247M0201 rev B 6 www abb com jokabsafety 2013 04 11 3 Connections See Chapter Installation and Maintenance for more information regarding installation Connections EStrongZ EstrongZ explosion proof...

Page 7: ...amp will illuminate Red When 24VDC is applied to the Green wire or Terminal 3 the lamp will illuminate Green If the LED is fitted but is not used ensure the conductors remain coiled and fixed away fro...

Page 8: ...2TLC172247M0201 rev B 8 www abb com jokabsafety 2013 04 11 5 Application examples...

Page 9: ...2TLC172247M0201 rev B 9 www abb com jokabsafety 2013 04 11...

Page 10: ...for M4 screws NB All measurements are in mm Accessories Type Article number Description Gland 2TLA050040R0002 Stainless steel cable gland M20 x 1 5 Conduit Plug 2TLA050040R0004 Stainless steel condui...

Page 11: ...urrent lth 10 A Rated insulation withstand voltages 500 VAC 2500 VAC Short circuit overload protection Fuse externally 10 A FF Explosion Proof version X Classification Ex d IIC T6 20 C Ta 60 C Gb Ex t...

Page 12: ...PL e cat 4 depending on system architecture EN 62061 Up to SIL3 depending on system architecture Safety data Mechanical reliability B10d PFHD Proof test interval life MTTFd 1 500 000 operations at 10...

Page 13: ...2TLC172247M0201 rev B 13 www abb com jokabsafety 2013 04 11 8 EC Declaration of conformity...

Page 14: ...2TLC172247M0201 rev B 14 www abb com jokabsafety 2013 04 11 ABB AB JOKAB SAFETY Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety...

Reviews: