![ABB EStrong Series Original Instructions Manual Download Page 12](http://html1.mh-extra.com/html/abb/estrong-series/estrong-series_original-instructions-manual_4344490012.webp)
2TLC172247M0201, rev. B
12
www.abb.com/jokabsafety
2013-04-11
Safety-related characteristic data and Conformity
Conformity
European Machinery Directive 2006/42/EC
EN ISO 12100:2010, EN ISO 13850:2008, EN 60204-
1:2006+A1:2009
EN 60947-
1:2007+A1:2011, EN 60947
-5-
1:2004+A1:2009,
EN 60947-5-
5:1997+A1:2005
EN ISO 13849-1
Up to PL e, cat. 4 depending on system architecture
EN 62061
Up to SIL3 depending on system architecture
Safety data
Mechanical reliability B
10d
PFH
D
Proof test interval (life)
MTTF
d
1 500,000 operations at 100 mA load
<1.0 x 10-7
21 years
214 years (8 cycles per hour/24 hours per day/365 days per year)
Certifications
TÜV, cULus
Information with regard to UL 508
Use 12AWG copper conductors only
Electrical Rating: A300 48W5
Type 1 Enclosure
Max. Switching Current / Volt / Amp: 120V 6A (720VA break) PF 0.38,
240V 3A (720VA break) PF 0.38