Maintenance 

 

Warning!  

The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the 
safety functions are working properly (EN 62061:2005).

 

In case of breakdown or damage to the product, contact the nearest ABB Jokab Safety Service Office or reseller. 
Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, 
impairing the safety of the device which in turn could lead to serious injury to personnel. 

Testing of the safety functions 

Make sure the safety unit is working properly by following these steps: 

 

Interrupt protection by moving Eva away from Adam. The LED will light red when Eva is out of position 
relative Adam. 

 

Interrupt the dynamic safety circuit before this unit. The LED will flash between green and red. 

 

Move Eva to position next to Adam. The LED will light green if the safety circuit(s) before this unit is not 
interrupted. 

An additional function test can be made by slowly moving Eva away from Adam. The LED will flash fast between 
green and red when Eva is 2 mm from max sensing distance to Adam. 

Troubleshooting 

LED indication 

Expected causes of faults 

Checking and measures to take 

Lights red 

Eva away 

Move Eva closer to Adam 

Metal (iron) between Eden 

Remove the metal 

24 VDC input to pin-2 (no dynamic signal) 

Check if there is 24 VDC to input (pin-2). If Yes, check 
cable or unit before and fix it. 

No lights 

Loss of power supply 

Check 24 VDC / 0 VDC power supply 

Lights green (but no dynamic output 
detected) 

Defected dynamic signal input to unit 
(asymmetric pulses) 

Check the dynamic input or the unit before 

Lights green/red (flashing) 

No dynamic input (Eva in position with 
Adam), or info-output (pin-5) connected to 
0 VDC 

Check the unit before (make it active). Check the info-
output, fix it. 

Weak lights or red and green lights at 
the same time 

The unit is defect 

The unit needs to be replaced. Contact ABB Jokab 
Safety. 

 

Warning! 

Replace a defected unit with a new one and 

never

 bypass the safety circuit using Tina 1A or any other 

solution. 

 

Please note!

This model of Eden is obsolete and has been replaced by Eden DYN

Summary of Contents for Eden

Page 1: ...b Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Original instructions Eden Non contact safety sensor Please note This model of Eden is obsolete and has been replaced by Eden DYN ...

Page 2: ...rty certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attention must be given This is not intended ...

Page 3: ...y regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 9 Installation precautions 10 Maintenance 11 Testing of the safety functions 11 Troubleshooting 11 5 Operation 12 LED indication 12 Information output signal attributes 12 6 Model overview 13 Accessories 13 7 Technical data 14 8 EC Declaration of conformity 17 Please note This model of Eden is obsolete and has bee...

Page 4: ... the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipment An instruction or procedure which...

Page 5: ...roduct with articlenumber beginning with 2TLJ is fully compatible with the ABB branded product with articlenumber beginning with 2TLA Safety regulations Warning Carefully read through this entire manual before using the device The devices shall be installed by a trained electrician following the Safety regulations standards and the Machine directive Failure to comply with instructions operation th...

Page 6: ...utput able to indicate the status of the sensor The information channel output is non safe and should never be used for the safety function The only signals intended for safety functions are the safe dynamic signals M12 5 pole male seen from cable side M12 5 pole female seen from cable side M12 connector 5 pole male 1 Brown 24 VDC 2 White Dynamic signal input 3 Blue 0 VDC 4 Black Dynamic signal ou...

Page 7: ... 02 09 Connection examples Connection example Two Eden and one Spot T R connected to Pluto safety PLC Caution All cable colours according to ABB Jokab Safety standard cables ABB Please note This model of Eden is obsolete and has been replaced by Eden DYN ...

Page 8: ...absafety 2015 02 09 Connection example Different sensors connected to Vital 1 safety module Caution All cable colours according to ABB Jokab Safety standard cables Please note This model of Eden is obsolete and has been replaced by Eden DYN ...

Page 9: ...M4x25 Eden E are recommended Use max tightening torque 2 Nm Lock screw using Loctite or similar to prevent easy dismounting if necessary refer to risk assessment Eden installation Maximum sensing distance between Adam and Eva Eden 15 mm 2 mm Eden E 12 mm 2 mm Minimum distance between two Eden pairs 50 mm The DA2 mounting spacer must be used in order to physically protect Eden from damage Mounting ...

Page 10: ...body 1600 mm s T the total time from opening of the guard until the hazardous machine movement has stopped i e including control system reaction times and other delays s C a safety distance taken from Table 4 or Table 5 of EN ISO 13857 2008 if it is possible to push fingers or a hand through the opening towards the hazard before a stop signal is generated NB In some cases T might be reduced by the...

Page 11: ...rupted An additional function test can be made by slowly moving Eva away from Adam The LED will flash fast between green and red when Eva is 2 mm from max sensing distance to Adam Troubleshooting LED indication Expected causes of faults Checking and measures to take Lights red Eva away Move Eva closer to Adam Metal iron between Eden Remove the metal 24 VDC input to pin 2 no dynamic signal Check if...

Page 12: ... Dynamic signal input does not exist i e the safety circuit is interrupted before this unit 24 VDC A constant 24 VDC signal is applied high H 0 VDC The pin is connected to 0 VDC low L The information output signal depends on the input signal according to the table below Note that if the safety is interrupted i e if Eva is away from Adam the information output signal is always low L Input signal pi...

Page 13: ...r 0 5 m protective housing IP69K Adam E 20 m 2TLA020051R0800 Adam E 5 pole cable 20 m protective housing IP69K Some Eden models are available in grey refer to your ABB Jokab Safety sales representative for more information Accessories Type Article number Description DA1 2TLA020053R0000 Protection plate DA2 2TLA020053R0100 Mounting spacer 2TLA020053R4200 Safety screw SM4 x 20 for mounting Adam and ...

Page 14: ... m 5 pole cable 10 m Adam 10 m Adam E 10 m 5 pole cable 20 m Adam 20 m Adam E 20 m Cables 5 pole screen Material PVC UL2464 Cable size ø5 7 mm Conductor size 0 34 mm2 Size See drawings below Mechanical life 107 cycles Weight Eva 26 g Eva E 36 g Adam M12 30 g Colour Yellow or grey depending on model black text Maximum detection distance Hysteresis approx 1 mm Eden 15 2 mm Eden E 12 2 mm Assured rel...

Page 15: ...category 4 Certificates TÜV Nord The Jokab Safety branded product with article number beginning with 2TLJ is fully compatible with the ABB branded product with article number beginning with 2TLA Intended use NB These restrictions are only according to certification for CSA Canada USA Pollution degree 2 Installation category N A Altitude 2000 m max Humidity 80 max for temperatures up to 31 C and 35...

Page 16: ...2TLJ172066M0201 rev F 16 www abb com jokabsafety 2015 02 09 Eden E dimensions NB All measurements in millimetres Please note This model of Eden is obsolete and has been replaced by Eden DYN ...

Page 17: ...w abb com jokabsafety 2015 02 09 8 EC Declaration of conformity ABB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Please note This model of Eden is obsolete and has been replaced by Eden DYN ...

Reviews: