![ABB DCT880 Service Manual Download Page 41](http://html.mh-extra.com/html/abb/dct880/dct880_service-manual_3058041.webp)
41
Exchange SDCS-CON-F
General
All DCT880 size T1 … T5 are equipped with the same controller board SDCS-CON-H, thus the exchange of
the board is similar for all unit sizes.
Required Tools
Special tools or material needed in addition to standard tools for the exchange of the SDCS-CON-H:
−
Torx screwdrivers:
TX10, TX20, TX25
Before the work is started, disconnect the thyristor power controller completely from
the power supply, then check the voltage free condition and make sure, everything is
located in an electrical and mechanical safe condition!
Overview SDCS-CON-H exchange
1. Write down type code of the thyristor power controller.
2. Set jumpers on the new SDCS-CON-H according to the old SDCS-CON-H.
3. Exchange the electronic tray with SDCS-CON-H.
4. Set type code of the thyristor power controller.
1. Write down type code of the thyristor power controller
Write down the contents of 95.16 Set: Unit type code. This information must be set in the new SDCS-CON-H
manually.
2. Set jumpers on the new SDCS-CON-H according to the old SDCS-CON-H
Copy the jumper settings (J1 … J6) of the old SDCS-CON-H onto the new SDCS-CON-H accordingly.
Exchange SDCS-CON-H
3ADW000449R0101 DCT880 Service Manual e a
Summary of Contents for DCT880
Page 1: ...DCT880 Service Manual DCT880 Thyristor power controller 20 A 4160 A ...
Page 2: ......
Page 85: ...85 T2 160 A 245 A Appendix A Spare Parts List 3ADW000449R0101 DCT880 Service Manual e a ...
Page 86: ...86 T3 325 A 420 A Appendix A Spare Parts List 3ADW000449R0101 DCT880 Service Manual e a ...
Page 87: ...87 T4 550 A 740 A Appendix A Spare Parts List 3ADW000449R0101 DCT880 Service Manual e a ...
Page 88: ...88 T5 890 A 960 A Appendix A Spare Parts List 3ADW000449R0101 DCT880 Service Manual e a ...
Page 89: ......