Note:
Syntax error indicates EMI (Electromagnetic interference) in the in-
stallation.
•
check grounding
•
switch off all other electronic equipment
•
close and re-open HyperTerminal
Flash Erase
•
Type
ls
(+ Return).
Flash Program
•
Type
rp
(+ Return).
•
Terminal program shows a small
rp
•
Open menu item TRANSFERS / SEND TEXT FILE… and select
the suitable firmware
Attention:
Use
DC21A2yy.rom
with
DCS 500B
and
DC15A2yy.rom
with
DCS 600
.