Page 1: ... Operating Instructions CP600 Control Panels CP650 x CP650 WEB x CP660 x CP660 WEB x CP675 x CP675 WEB x ...

Page 2: ... Specifications 7 Environmental Conditions 7 Electromagnetic Compatibility EMC 8 Durability Information 9 Technical Data 10 Dimensions 11 Installation Environment 12 Applying the Rectangular Gasket 12 Installation Procedure 13 Connections 14 PLC Port 14 PC Printer Port 16 Ethernet Port 16 Power Supply Grounding and Shielding 17 AUX Port 18 Battery 19 Cleaning Faceplates 20 Getting Started 21 ...

Page 3: ...Operating Instructions 2 CP600 Issue 12 2011 System Settings 22 Dedicated LED Indicators 24 Unpacking and Packing Instructions 25 ...

Page 4: ...these devices into the residential commercial and light industrial environments is al lowed only in the case that special measures are taken in order to get the conformity to IEC 61000 6 3 The products are in compliance with the restrictions on Certain Hazardous Substances RoHS Directive 2002 95 EC This Operating Instruction describes the main features of the CP600 Control Panels The Operating In ...

Page 5: ...f not avoided CAUTION Indicates a possible risk It may lead to light or slight injury or material damage if not avoided Markups Enumeration Precondition for an operation instruction or a description Operation instruction with one step 1 Operation instruction with several steps Result of an operation NOTE Helpful information with background information or an emphasized notice TIP Application tips o...

Page 6: ...le languages to meet global requirements Far East languages are supported Tools available in PB610 Panel Builder 600 support easy third party translations and help reducing development and maintenance costs of the application Data display in numerical text bargraph analog gauges and graphic image formats Rich set of state of the art HMI features Data acquisition alarm handling scheduler and timed ...

Page 7: ...sures are taken in order to get the conformity to EN 61000 6 3 Product Identification The Control Panel products are identified by a product label The label reports several information includ ing the model name the part number the power supply the date of production in the following format ywwy and two barcodes The first code is the version code the second one the serial number S N Example of prod...

Page 8: ... Control Panel unit s level of resis tance is equivalent to these standards oils that should have no effect on the Control Panel can possibly harm the unit This can occur in areas where either vaporized oils are present or where low viscosity cut ting oil are allowed to adhere to the unit for long periods of time If the Control Panel s front face protec tion sheet becomes peeled off these conditio...

Page 9: ...vel 2 kV L1 L2 PE 1 kV L1 L2 EN 61000 4 5 Signal port Level 1 kV line to earth Immunity to conducted dis turbances inducted by radio frequency field 0 15 80 MHz 10 V EN 61000 4 6 Voltage dips short interrup tions and voltage variations immunity test Port AC mains Level 0 duration 1 cycle and 250 cycles 50 Hz or 300 cycles 60 Hz 40 duration 10 cycles 50 Hz or 12 cycles 60 Hz 70 duration 25 cycles 5...

Page 10: ... Front foil silk screen without directly expose to sunlight or UV ray 10 years if the surrounding temperature is 25 C UV Resistance Indoor applications After 300 hrs cycled humidity in QUV some yellowing and brittleness may be present Touch panel resistive film analog 1 000 000 or more of activations see 2 1 Extended use in environments where the surrounding air temperature is 40 C or higher may d...

Page 11: ...t RS 232 RS 485 RS 422 RS 232 RS 485 RS 422 RS 232 RS 485 RS 422 Programming printer port RS 232 RS 485 RS 422 RS 232 RS 485 RS 422 RS 232 RS 485 RS 422 Aux port optional field bus Ethernet Yes Yes Yes Ethernet programming Yes Yes Yes Ethernet port 10 100 Mbit s 10 100 Mbit s 10 100 Mbit s USB port Host interface version 2 0 Host interface version 2 0 Host interface version 2 0 Graphic Yes Yes Yes...

Page 12: ...0 WEB x 326 9 30 256 10 1 42 1 65 267 10 51 337 13 26 CP675 WEB x 381 15 296 11 65 46 1 82 307 12 1 392 15 43 Model CSD Minimum compass safe distance of standard compass CSD2 Minimum compass safe distance of steering compass standby steering compass and emergency compass mm inches mm inches CP650 WEB x 400 15 74 250 9 84 CP660 WEB x 500 19 68 300 11 81 CP675 WEB x 650 25 60 400 15 74 ...

Page 13: ...he panel or the touchscreen In order to meet the front panel protection classifications proper installation procedure must be followed The borders of the cutout must be flat The cutout for the panel must be of the dimensions indicated in this manual Screw up each fixing screw until the plastic bezel corner get in contact with the panel The IP66 is guaranteed only if Maximum deviation from the plan...

Page 14: ...Operating Instructions 13 CP600 Issue 12 2011 Installation Procedure Place the fixing brackets CAUTION Screw each fixing screw until the bezel corner gets in contact with the panel ...

Page 15: ...r Different electrical standards are available for the signals in the PLC port connector RS 232 RS 422 RS 485 The used cable selects the appropriate signals NOTE It is always necessary to use the correct cable type to connect on the PLC If the proper cable is not used communication with the PLC will not be possible The connector is a DB 9 pin female Pin Description Pin Description Pin Description ...

Page 16: ...le The communication cable must be chosen for the type of device being connected Connection to an AC 500 with the TK681 CP600 AC500 RS232 communication cable Connection to an AC 500 eCo with the TK682 CP600 AC500 eCo RS485 communication cable 1 Shield 2 SubD9 male ...

Page 17: ...e to connect on the PLC If the proper cable is not used communication with the PLC will not be possible The connector is a DB 9 pin female Pin Description Pin Description Pin Description 1 GND 4 RX CHB 7 CTS CHB 2 5 8 RTS CHA 3 TX CHA 6 5 V output 9 The communication cable must be chosen for the type of device being connected Ethernet Port Ethernet Port A OFF No activity BLINKING Activity B ON Val...

Page 18: ...ted near the power supply terminal block A label helps identify the ground connection 2 Connect to ground the terminal 3 on the power supply terminal block 3 The power supply circuit may be floating or grounded In the latter case connect to ground the power source common as shown in the figure below with a dashed line When using the floating power scheme note that the panes internally connects the...

Page 19: ...ity of the AUX port depends on the optional Communi cation Module which is plugged into the unit NOTE The pin assignment of the AUX port connector is described in the manual of the Communi cation Module WARNING Do not plug the Communication Module and the ETAD adapter when power is applied to the operator panel 1 Open the housing 2 Insert the Communication Module pressing simultaneously on the fou...

Page 20: ...ry maintains the hardware real time clock date and time Charging the Battery At first installation recharge the battery for 48 hours When the battery is charged it assures a period of 3 month of data back up at 25 C Recycling and Disposal The battery must not be disposed as unsorted domestic waste Dispose the battery according to the local regulations ...

Page 21: ...Operating Instructions 20 CP600 Issue 12 2011 Cleaning Faceplates The equipment must be cleaned only with a soft cloth and neutral soap product Do not use solvents ...

Page 22: ...application and must be properly in stalled The Windows TM environment is not included in the software package PB610 Panel Builder 600 and must already be installed on the PC PB610 Panel Builder 600 uses the PC Ethernet interface to communicate with the target device Make sure that the proper firewall policy is configured in order to allow PB610 Panel Builder 600 to access the network The version ...

Page 23: ...time parameter that could have been changed Please contact your panel supplier for any additional information or use the System Mode activating it with the tap tap special procedure Tap tap consists in a high frequency sequence of touch activations by simple means of the finger tapping the touchscreen performed during the power up and started immediately after the panel is powered User Mode User M...

Page 24: ...perating system see be low in the next chapter for additional details Download Splash Image allows changing the splash screen image displayed by the unit at power up the image should be provide in a specific format We suggest to update Splash Screen Image di rectly from Studio software which supports this feature starting from V 1 50 Download Bootloader allows to check current version of the syste...

Page 25: ...LED in the upper left part of the front below the red stripe The meaning of the LED indicator is explained in the following table LED color Status Meaning Red Blinking Battery low or alarm requires acknowledgment On Hardware fault Green Blinking Communication error On Normal operation ...

Page 26: ...Operating Instructions 25 CP600 Issue 12 2011 Unpacking and Packing Instructions To repack the unit follow the instructions backwards ...

Page 27: ...utomation Products GmbH Wallstadter Str 59 68526 Ladenburg Germany Telephone 49 0 6221 701 1444 Telefax 49 0 6221 701 1382 E Mail plc support de abb com Internet http www abb com PLC Manual No 2CDC159006M0202 ...