Page 1: ...OPER ATING INSTRUCTION Control Panels CP600 eCo CP604 B CP607 B CP610 B...

Page 2: ...ns 7 4 Technical data 9 4 1 Dimensions 11 4 2 Installation environment 14 4 3 Installation procedure 15 5 Connections 16 5 1 Serial port 19 5 2 Ethernet port 20 6 Power supply grounding and shielding...

Page 3: ...nspor tation storage assembly use and maintenance The Manual refers to the following models CP604 Control panel with TFT color 4 3 widescreen display touchscreen CP607 Control panel with TFT color 7 w...

Page 4: ...s of severity DANGER indicates a failure to observe safety rules and such failure may cause death or serious injuries ATTENTION indicates a failure to observe safety rules and that deficiency may caus...

Page 5: ...ects Multilanguage applications with TrueType fonts Easily create install and maintain applications in multiple languages to meet global requirements Data display in numerical text bargraph analog gau...

Page 6: ...allo wed only in the case that special in measures are taken in order to ensure conformity to EN 61000 6 3 In compliance with the above regulations the products are CE marked Product identification Th...

Page 7: ...ntrol panel installed in a solid panel has been tested using conditions equiva lent to the standards shown in the Environmental conditions Even though the level of resistance of the control panel is e...

Page 8: ...ness may be present Solvent resistance Contact for 1 2 hour at 21 C No visible effect Acetone Butyl Cellosolve Cyclohexanone Ethyl Acetate Hexane Isopropyl Alcohol MEK Methylene Chloride Toluene Xylen...

Page 9: ...60 MB Flash RAM 256 MB DDR 256 MB DDR Serial Port RS 232 RS 485 RS 422 software configurable RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 10 100 Mbit 10 100 Mbit USB port Host i...

Page 10: ...inches 10 1 widescreen Dimming yes User memory 60MB Flash RAM 512 MB DDR Serial Port RS 232 RS 485 RS 422 software configurable Ethernet port 10 100 Mbit USB port Host interface V2 0 max 500mA Real Ti...

Page 11: ...11 MODEL A B L H D T CP604 136mm 5 35 96mm 3 78 147mm 5 78 107mm 4 21 29mm 1 14 5mm 0 19 4 1 Dimensions Technical data Cut out Fig 4 1...

Page 12: ...12 MODEL A B L H D T CP607 176mm 6 90 136mm 5 35 187mm 7 36 147mm 5 79 29mm 1 14 5mm 0 19 Technical data Cut out Fig 4 2...

Page 13: ...13 MODEL A B L H D T CP610 271mm 10 66 186mm 7 32 282mm 11 10 197mm 7 75 29mm 1 14 6mm 0 23 Cut out Fig 4 3 Technical data...

Page 14: ...sunlight This might accelerate the aging process of the front panel film The equipment is not intended for installation in contact with corrosive chemical compounds Check the resistance of the front...

Page 15: ...3 Installation procedure Place the fixing brackets as shown in figure Fig 4 5 CAUTION Screw each fixing screw until the bezel corner gets in contact with the panel Tightening torque 75 Ncm Technical...

Page 16: ...16 5 Connections 1 Serial Port 2 Ethernet Port 3 USB Port 4 Power Supply Fig 5 1 Connections CP604...

Page 17: ...17 1 Serial Port 2 Ethernet Port 3 USB Port 4 Power Supply Fig 5 2 Connections CP607...

Page 18: ...18 1 Serial Port 2 Ethernet Port 3 USB Port 4 Power Supply Fig 5 3 CP610 Connections...

Page 19: ...ignals in the PLC port connector are RS 232 RS 422 RS 485 The serial port is software programmable Make sure you select the appropriate interface in the programming software The communication cable mu...

Page 20: ...rnet port have two LED indicators for status Please see description below LED indicators Green Yellow ON OFF No LAN cable connected BLINK link active ON LAN cable connected with 100Mbit s link BLINK l...

Page 21: ...tter case connect to ground the power source common as shown in figure with a dashed line When using the floating power scheme note that the CP600 devices internally connects the power common to groun...

Page 22: ...nstalled on a computer running Microsoft Windows There are two options to transfer a PB610 B application project to a CP600 device Ethernet Connect the CP600 device to the computer with an Ethernet ne...

Page 23: ...rough the available options The active item of menu is highlighted on the left side The right side shows related information and settings Based on the size of the CP600 screen both menu and content of...

Page 24: ...old few seconds selecting so RESTART CONFIG OS to boot in System Mode System Settings includes options for basic settings of the device Language Configure language used for System Setting menu only Sy...

Page 25: ...cedure at boot this procedure consists in tapping the surface of the touchscreen during the device power up phase Tapping frequency must be high You have to start tapping the touchscreen as soon as po...

Page 26: ...es or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB AG does not accept any responsibility whatsoever for potential e...