background image

Operating Instructions 

 

 

Busch-Wächter

®

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

Operating Instructions | 1473-1-8140 

— 2 — 

   

Pos: 4 /#Neustruktur#/Online-Dokumentation (+KNX)/Inhaltsverzeichnis (--> Für alle Dokumente <--)/Inhaltsverzeichnis @ 19\mod_1320649044386_15.docx @ 109653 @  @ 1 

 

 

1

 

Intended use ............................................................................................................................................................ 3

 

2

 

Environment ............................................................................................................................................................. 3

 

3

 

Setup and function ................................................................................................................................................... 4

 

3.1

 

Features of function and equipment ........................................................................................................ 4

 

3.2

 

Possible combinations ............................................................................................................................ 5

 

4

 

Operation ................................................................................................................................................................. 6

 

4.1

 

Brightness switching threshold ................................................................................................................ 7

 

4.2

 

Presence simulation ................................................................................................................................ 7

 

4.3

 

Continuous light ...................................................................................................................................... 7

 

5

 

Technical data.......................................................................................................................................................... 8

 

6

 

Start-up .................................................................................................................................................................... 8

 

7

 

Commissioning ........................................................................................................................................................ 9

 

7.1

 

Removing the protective foil .................................................................................................................... 9

 

7.2

 

Programming the device ......................................................................................................................... 9

 

8

 

Maintenance ............................................................................................................................................................ 9

 

8.1

 

Battery change of remote control ............................................................................................................ 9

 

 

=== Ende der Liste für Textmarke TOC === 

 

Summary of Contents for Busch-Wachter

Page 1: ...ting Instructions Busch Wächter Pos 2 Neustruktur Online Dokumentation KNX Titelblätter Waechter Titelblatt 6841 IR Handsender 28 mod_1347354023887_15 docx 232625 1 6841 101 500 IR remote control Ende der Liste für Textmarke Cover ...

Page 2: ...nded use 3 2 Environment 3 3 Setup and function 4 3 1 Features of function and equipment 4 3 2 Possible combinations 5 4 Operation 6 4 1 Brightness switching threshold 7 4 2 Presence simulation 7 4 3 Continuous light 7 5 Technical data 8 6 Start up 8 7 Commissioning 9 7 1 Removing the protective foil 9 7 2 Programming the device 9 8 Maintenance 9 8 1 Battery change of remote control 9 Ende der Lis...

Page 3: ...evices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot Do not dispose of the batteries with domestic waste Take the used batteries to the collecting depot for recycling Many retailers have collection boxes for used batteries Pos 8 3 Neustruktur Online Dokumentation KNX S...

Page 4: ...or The IR remote control serves for adjusting Busch Watchdog devices The IR remote control 6841 101 can only be operated with Bush Watchdogs 110 MasterLINE and 220 280 MasterLINE Pos 12 Neustruktur Online Dokumentation KNX Überschriften Für alle Dokumente 2 Ebene A F Funktions und Ausstattungsmerkmale 23 mod_1336557630140_15 docx 209136 22222 1 3 1 Features of function and equipment Pos 13 Neustru...

Page 5: ...le combinations Pos 16 Neustruktur Online Dokumentation KNX Kombinationsmöglichkeiten Waechter Kombinationsmöglichkeiten 6841 101 IR Handsender 28 mod_1347357889716_15 docx 232722 111 1 6841 101 6855 110 MasterLINE X 6847 220 MasterLINE select X 6848 220 MasterLINE premium X 6847 6867 220 280 MasterLINE X Pos 17 Neustruktur Online Dokumentation KNX Steuermodule Online Dokumentation Für alle Dokume...

Page 6: ... Operation The following settings can be made with the IR remote control No Function 1 Resetting the brightness limit value to the settings of the potentiometers on the device 2 Setting the current brightness as brightness limit value 3 Deactivation of presence simulation 4 Activation of presence simulation Continuous light between twilight and 22 30 p m CET or 23 30 CEST Followed by movement dete...

Page 7: ...itchover to automatic mode at approximately 22 30 p m When presence simulation is activated this gives the impression that persons are present in the house and is therefore ideal for when you are away on holiday 4 3 Continuous light Continuous OFF lamp is crossed out The movement detector is activated for four hours It then automatically returns to the prior operating mode AUTO Early pressing of t...

Page 8: ...ype IP 40 Pos 23 Neustruktur Online Dokumentation KNX Überschriften Für alle Dokumente 1 Ebene A F Erstinbetriebnahme 17 mod_1299234649340_15 docx 100978 2212222 1 6 Start up Pos 24 Neustruktur Online Dokumentation KNX Erstinbetriebnahme Waechter Erstinbetriebnahme 6841 IR Handsender 29 mod_1347603166970_15 docx 233604 22122 1 Note The IR remote control is coded and must be programmed to the Busch...

Page 9: ...ter activating the power on the Busch Watchdog The Busch Watchdog must be de energized for at least 30 seconds The remote control will then automatically connect itself to the Busch Watchdog and the Busch Watchdog will flash if the reception is correct Repeat these steps to program a maximum of 9 additional remote controls Pos 28 Neustruktur Online Dokumentation KNX Überschriften Für alle Dokument...

Page 10: ...e reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The documen...