Information about planning and application
System Manual 2CKA001473B9577
│
87
DA
-
DA
+
1C
N
L
N
NS
DA
-
DA
+
LS
NS
DA
-
DA
+
LS
DA
-
DA
+
L
N
3
5
4
1
2
7
N
L
V
6
N
L
16A
Fig. 39: Examples of switching: DALI light control (main units/extension units) with extension unit input and fa control for
WC facility
[1] 6819/35-xxx-500 Universal BT, DALI
[2] When using voltage enabling of DALI operating devices
[3] 6819/39-xxx-500 Universal, DALI extension unit
[4] 6819/39-xxx-500 Universal, DALI extension unit
[5] DALI lamp
[6] Fan
[7] Extension unit push-button