Information about planning and application
System Manual 2CKA001473B9577
│
80
4.2.5
Open-plan office – Extension of the detection range with main units - Extension unit
communication
Function
The lighting with fluorescent tube in a larger office is to be controlled via a Busch-Presence
detector. Three Busch-Presence detector are to be installed in parallel to detect the entire area.
In addition, the user would like to switch the lighting on and off manually via a push-button.
Installation and settings
Fig. 32: Application example: open-plan office
For optimum detection, the installation positions of the Busch-Presence detector should be
directly above the workplaces.
The Busch-Presence detector have an almost circular detection range. The areas should
overlap slightly to ensure that there are no gaps in the detection.