INTRODUCTION
SPECIFICATIONS
1 - 6
SPECIFICATIONS
Table
provides performance specifications of the Type AV3
and Type AV4 positioners. Tables
and
provide perfor-
mance specifications for the position transmitters.
Table 1-3. Type AV 3/4 Positioner Specifications
Property
Characteristic/Value
Input Range
Type AV3
4 to 20 mA DC (30 VDC maximum)
Type AV4
Computer DDC (direct digital control), solid state or contact closure
input.
Units have 50% range suppression and/or zero elevation capability.
Minimum pulse width test data taken at 20
°
C (68
°
F) and factory pre-
set fine speed adjustment. Operation at other fine speed adjustment
settings will require different minimum pulse widths. Operation at
colder temperatures may require longer minimum pulse widths.
Voltage Supply (Type AV4
only)
Minimum
16 VDC
Nominal
24 VDC
Maximum
34 VDC
NOTE:
Maximum 50 mA current draw.
Input Impedance
1
<1.66 k
Ω
at 4 mA
<0.57 k
Ω
at 12 mA
<0.35 k
Ω
at 20 mA
Standard Stroke Range
(cam selection)
Type AV
1 positioner
12.7 to 50.8 mm (0.5 to 2.0 in.) linear, rotary input 45
°
Type AV
2 positioner
25.4 to 101.6 mm (1.0 to 4.0 in.) linear, rotary input 90
°
NOTE:
It is recommended that the 90° cam be used wherever possible (Type AV
2
po-
sitioner).
Gain
Two adjustment levels by changing gain hinge spring.
Accuracy
1,2
0.70% of span typical; <0.90% of span maximum
Resolution
<0.30% of span maximum
Hysteresis
1,2
0.35% of span typical; <0.60% of span maximum
Repeatability
1,2
0.40% of span typical; <0.60% of span maximum
Minimum Pulse Width
Coarse Speed
Adjustment Position
Msecs
4
40
3
20
2
15
1
12.5