AquaProbe FEA100 / FEA200
Electromagnetic flowmeter – insertion-type flow sensors
6 Specification
OI/FEA100/200–EN Rev. D
25
Maximum Flow
The maximum velocity depends upon the actual insertion length. Typical insertion lengths are 0.125 and 0.5 x pipe
diameter.
The graph is a guide* to the maximum allowable velocity for different insertion lengths.
*The graph is intended as a guide only. Factors that influence the maximum insertion length into the pipe include: flow
sensor mounting components, for example, standoffs, bushes and valves; other influences include pipeline vibration,
fluid vibration and pump noise.
Wetted Materials
Body
Stainless steel
Flow Sensor
Suitable for potable water (WRAS listed)
Electrodes – stainless steel 316L
Seals
Suitable for potable water (WRAS listed)
Temperature Ranges
1000
0
100 200 300 400 500 600 700 800 900
0
1.0
2.0
3.0
4.0
5.0
6.0
mm
39
0 3
6
9 12 15 18 21 24 27 30 33 36
in
.
20
5
10
15
0
ft/s
econd
Max
imum velocity m/s
Actual Insertion Length
Process
Ambient
Storage
60 °C (140 °F)
0 °C (32 °F)
60 °C (140 °F)
–20 °C (–4 °F)
70 °C (158 °F)
–20 °C (–4 °F)