MoTor InsTAllATIon In vEhIClE
19
4.3. Electrical installation
The motor needs an inverter to operate. The inverter must be able to supply 3 phase AC current and be
capable of controlling the motor. The motor has been tested and optimized together with the ABB
HES880 inverter. An inverter with a different control strategy, switching frequency and pulse pattern
might have an impact on the motor performance. For more information about the HES880 inverter,
please contact your local ABB sales office.
4.3.1. High voltage connection
Motors for heavy electrical vehicles, type AMXE132
Introduction
3BSY600011-BCM
6 (34)
Chapter 1
Introduction
1.1
General
The purpose of this document is to describe general guidelines for the installation, maintenance
and disposal of the AMXE132 motor.
•
Actions shown in this manual are only to be performed by trained personnel authorized by
ABB or authorized by the end user.
The actual appearance of the motor may vary from the illustrations in this manual, depending on
the final design.
Abbreviations and nomenclature used in this manual:
•
D-end or DE: Drive side of motor.
•
ND-end or NDE: Non drive side of motor.
•
WARNING: signal word used to indicate a potentially hazardous situation which, if not
avoided, can result in death or serious injury.
Symbols used in this manual:
Caution, risk of electric shock.
Safety Alert Symbol, warns of a potential personal injury hazard.
Warning, magnetic field.
Prohibition, No access for people with active implanted cardiac devices
(pace maker)
Warning – High Voltage
Touching a live motor connection causes serious injuries or death.
The motor is equipped with a high voltage power connector, see Figure 1.
NOTE:
Ensure that the motor is disconnected from power supply prior to connecting or
disconnecting the high voltage power connector.
Installing power voltage at U-V-W will rotate traction motor counter-clockwise, facing traction motor
shaft from D-end. Make sure that all cable connections are installed in appropriate way and suitable for
high frequency currents.
There are two power connectors for each phase (U, V, W).
All six power connectors must be connected to power cables when setting the power supply to ON.
Earth cable from converter or chassis must be installed in appropriate way and be suitable for high
frequency currents.
Connector description
Type of connector
Type of connector
M12 male, 4-pole, B-coded
Resolver
M12 male, 8-pole, A-coded
HVIL (High Voltage Interlock Loop)
M12 male, 4-pole, B-coded
Power connectors (2x), phase W
PLOOX-301-10D8
Power connectors (2x), phase V
PLOOV-301-10D8
Power connectors (2x), phase U
PLOOU-301-10D8
Table 5.
Electrical connector specification, connection box.
NOTE:
Ensure that all cable connections are installed in an appropriate way and are suitable for high
frequency currents.