Manual for Induction Motors and Generators
Maintenance -
71
3BFP 000 050 R0101 REV E
7.5.2.5 Oil change schedule for mineral oils
For self-lubricated bearings cleaning intervals with oil changes of approximately 8000
operating hours are recommended and approx. 20000 operating hours for bearings with oil
circulation systems.
Shorter oil change intervals may be necessary in case of frequent start-ups, high oil
temperatures or excessively high contamination due to external influences.
The correct oil change interval can be found on the bearing plate and dimensional drawing, see
ISO VG 22
Viscosity 22 cSt
at 40 °C
ISO VG 32
Viscosity 32 cSt
at 40 °C
ISO VG 46
Viscosity 46
cSt at 40 °C
ISO VG 68
Viscosity 68
cSt at 40 °C
ISO VG 100
Viscosity 100
cSt at 40 °C
Environmentally
Benign Oils:
Aral
Vitam EHF 22
-
Vitam EHF
46
-
-
Mobil
-
EAL
Hydraulic Oil 32
EAL
Hydraulic Oil
46
-
-
Shell
-
Naturelle
HF-E 32
Naturelle
HF-E 46
Naturelle
HF-E 68
-
Mineral Oils:
Aral
Vitam GF 22
Vitam GF 32
Vitam GF 46
Vitam GF 68
Degol CL 100 T
BP
Energol CS 22
Energol CS 32
Energol CS
46
Energol CS 68 Energol CS 100
Castrol
Hyspin AWS 22 Hyspin AWS 32
Hyspin AWS
46
Hyspin AWS
68
Hyspin AWS
100
Chevron
Texaco Rando
HDZ 22
Texaco Rando
HDZ 32
Texaco
Rando HDZ
46
Texaco Rando
HDZ 68
Texaco Rando
HDZ 100
Esso
Nuto H 22
Terrestic T 32
Terrestic T
46
Terrestic T 68
-
Klüber
LAMORA HLP
32
LAMORA
HLP 46
LAMORA HLP
68
CRUCOLAN
100
Mobil
Velocite Oil No.
10
DTE Oil Light
DTE Oil
Medium
DTE Oil
Heavy
Medium
DTE Oil Heavy
Shell
Tellus S 22
Tellus S 32
Tellus S 46
Tellus S 68
Tellus S 100
Total
Azolla ZS 22
Azolla ZS 32
Azolla ZS 46 Azolla ZS 68
Azolla ZS 100