Standard function blocks
371
Extensions
FIO_01_slot1
(10084)
Illustration
Execution time
8.6 µs
Operation
The block controls the four digital inputs/outputs (DIO1…DIO4) and two relay outputs
(RO1, RO2) of a FIO-01 Digital I/O Extension mounted on slot 1 of the drive control unit.
The state of a DIOx conf input of the block determines whether the corresponding DIO
on the FIO-01 is an input or an output (0 = input, 1 = output). If the DIO is an output, the
DOx input of the block defines its state.
The RO1 and RO2 inputs define the state of the relay outputs of the FIO-01 (0 = not
energised, 1 = energised).
The DIx outputs show the state of the DIOs.
Inputs
Digital input/output mode selection (DIO1 conf … DIO4 conf): Boolean
Digital output state selection (DO1…DO4): Boolean
Relay output state selection (RO1, RO2): Boolean
Outputs
Digital input/output state (DI1…DI4): Boolean
Error output (Error): DINT (0 = No error; 1 = Application program memory full)
FIO_01_slot1
49
TLA1 1 msec
(1)
DIO1 conf
DIO2 conf
DIO3 conf
DIO4 conf
DO1
DO2
DO3
DO4
RO1
RO2
DI1
DI1(49)
DI2
DI2(49)
DI3
DI3(49)
DI4
DI4(49)
Error
Error(49)
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...