Standard function blocks
359
REAL24_TO_REAL
(10027)
Illustration
Execution time
1.20 µs
Operation
Output (O) is the REAL equivalent of the REAL24 input (I).
The output value is limited to the maximum value of the data type range.
Example:
Inputs
Input (I): REAL24
Outputs
Output (O): REAL
REALn_TO_DINT
(10029)
Illustration
Execution time
6.45 µs
Operation
Output (O) is the 32-bit integer equivalent of the REAL/REAL24 input (I). Output O1 is
the integer value and output O2 is the fractional value.
The output value is limited to the maximum value of the data type range.
Example (from REAL to DINT):
When I = 2.04998779297, O1 = 2 and O2 = 3276.
Inputs
The input data type is selected by the user.
Input (I): REAL, REAL24
Outputs
Output (O1, O2): DINT
REAL24_TO_REAL
90
TLA1 1 msec
(1)
I
O
O(90)
I = 0010 0110 1111 1111 1111 1111 0000 0000
Integer value
Fractional value
O = 0000 0000 0010 0110 1111 1111 1111 1111
Integer value
Fractional value
REALn_TO_DINT
(REAL)
91
TLA1 1 msec
(1)
I
O1
O1(91)
O2
O2(91)
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...