Parameters and firmware blocks
111
6.11
POS CORR STATUS
(page
)
Position correction status word.
Bit
Name
Val.
Information
0
HOMING START
1
Homing start is active. Source for the homing start is selected
by parameter
0
Homing start is inactive.
1
HOMING DONE
1
Homing has been performed.
0
Homing has not been performed (if bit 2 = 0) or homing is
being executed.
2
HOM DONE
ONCE
1
Homing has been performed at least once.
0
Homing has not been performed after power up or there is an
error with the actual position encoder.
3
COR DONE
ONCE
1
Cyclic correction has been performed at least once (
).
0
Cyclic correction has not been performed after power up or
there is an error with the actual position encoder.
4
POS LIM POS
1
Positive limit switch is active (source selected by parameter
).
0
Positive limit switch is inactive.
5
POS LIM NEG
1
Negative limit switch is active (source selected by parameter
).
0
Negative limit switch is inactive.
6
LATCH1 STAT
1
Position latch signal 1 is active (source selected by parameter
).
0
Position latch signal 1 is inactive.
7
LATCH2 STAT
1
Position latch signal 2 is active (source selected by parameter
).
0
Position latch signal 2 is inactive.
8
LATCH1 DONE
1
Position has been latched according to parameter
setting.
0
No position latch has occurred.
9
LATCH2 DONE
1
Position has been latched according to parameter
setting.
0
No position latch has occurred.
10
Reserved
11
POSIT AFTER
HOM
1
Drive is executing absolute positioning according to par.
after home position has been found and
set.
0
The drive has not reached home position yet.
12
CYC CORR
ACTIV
1
Cyclic correction is active.
0
Cyclic correction is inactive.
13
PRESET LATCH
STAT
1
Position preset mode is active (source selected by parameter
0
Position preset mode is inactive.
14
LATCH 1
TOGGLE
0
1 Position latch selected via
has been
stored anew.
15
LATCH 2
TOGGLE
0
1 Position latch selected via
has been
stored anew.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...