Parameters and firmware blocks
155
Group
These parameters select the data to be sent by the fieldbus controller to the drive,
and need to be set only if a fieldbus adapter module is installed. See also
on page
Notes:
• This parameter group is presented in the
User’s Manual
of the fieldbus adapter as
parameter group 2 or B.
• The new settings will take effect when the drive is powered up the next time
(before powering off the drive, wait at least 1 minute), or when parameter
is activated.
• The maximum number of data words is protocol-dependent.
53
53 FBA DATA OUT
53.01
FBA DATA OUT1
FW block: None
Selects data to be transferred from the fieldbus controller to the drive.
0
Not in use.
1
Control Word (16 bits).
2
Reference REF1 (16 bits).
3
Reference REF2 (16 bits).
11
Control Word (32 bits).
12
Reference REF1 (32 bits).
13
Reference REF2 (32 bits).
1001…9999
Parameter index.
53.02
FBA DATA OUT2
FW block: None
…
53.12
FBA DATA OUT12
FW block: None
See