392 Parameters
Displays the revolutions of (multiturn) encoder 2 within its
value range (see parameter
) as a
raw measurement.
This parameter is read-only.
-
0…16777215
Raw encoder 2 revolution count.
-
Displays the motor revolution count extension.
The counter is incremented when the position selected by
wraps around in the positive
direction, and decremented in the negative direction.
This parameter is read-only.
-
-2147483648 …
2147483647
Motor revolution count extension.
-
Displays the load revolution count extension.
The counter is incremented when the position selected by
wraps around in the positive
direction, and decremented in the negative direction.
This parameter is read-only.
-
-2147483648 …
2147483647
Load revolution count extension.
-
Status information related to the position counter function.
See section
(page
).
This parameter is read-only.
-
0000 0000b …
0111 1111b
Position counter status word.
1 = 1
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Value
0
Encoder 1
feedback
1 = Encoder 1 selected as load feedback source
1
Encoder 2
feedback
1 = Encoder 2 selected as load feedback source
2
Internal position
feedback
1 = Internal load position estimate selected as load feedback source
3
Motor feedback
1 = Motor feedback selected as load feedback source
4
Pos counter init
ready
0 = Position counter not initialized, or encoder feedback was lost.
Fresh counter initialization recommended.
1 = Position counter successfully initialized
5
Position counter re-
init disabled
1 = Position counter initialization is being prevented by par.
6
Position data
inaccurate
1 = Encoder feedback intermittent or lost. (If the drive is running,
estimated position is used whenever encoder feedback is
unavailable. If the drive is in stopped state, position counting will
continue based on encoder data after the connection is restored.)
7…15
Reserved
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...