390 Parameters
Displays the scaled load position in decimal format. The
position is relative to the initial position set by parameters
and
.
The number of decimal places is defined by parameter
Note:
This is a floating point parameter, and the accuracy is
compromised near the ends of the range. Consider using
parameter
instead of this
parameter.
This parameter is read-only.
-
-2147483.648 …
2147483.647
Scaled load position in decimal format.
-
Displays the calculated motor position.
The axis mode (linear or rollover) and resolution are defined
by parameters
and
respectively.
Note:
The position value can be sent on a fast time level to
the fieldbus controller by selecting
in either
This parameter is read-only.
-
-2147483.648 …
2147483.647
Motor position.
-
Displays the output of the position counter function as an
integer, enabling backwards compatibility with ACS 600 and
ACS800 drives. The position is relative to the initial position
set by parameters
and
), and the block diagram on page
.
This parameter is read-only.
-
-2147483648 …
2147483647
Scaled load position in integer format.
-
Displays encoder 1 speed in rpm.
This parameter is read-only.
-
-32768.00 …
32767.00 rpm
Encoder 1 speed.
See par.
Displays the actual position of encoder 1 within one
revolution.
This parameter is read-only.
-
0.00000000 …
1.00000000 rev
Encoder 1 position within one revolution.
32767 =
1 rev
Encoder 1 multiturn
revolutions
Displays the revolutions of (multiturn) encoder 1 within its
value range (see parameter
This parameter is read-only.
-
0…16777215
Encoder 1 revolutions.
-
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Page 4: ......
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 112: ...112 Application macros ...
Page 496: ...496 Additional parameter data ...
Page 544: ...544 Fault tracing ...
Page 602: ...602 Control chain diagrams ...