34 Signals and parameters
Parameters
No
Name/Value
Description
74
74 Centrifuge
Decanter control
Selecting Centrifuge or Decanter control.
74.01
Centrifuge/
Decanter function
selection
Selects Centrifuge or Decanter function.
Centrifuge
Not selected
Not selected.
0
Decanter
Decanter function is selected for drive operation.
Note:
Drive operates based on the setting in parameter
.
1
Centrifuge
Centrifuge function is selected for drive operation. See
parameter group
.
2
75
75 Centrifuge
function
Settings for Centrifuge operation sequence
control.
75.01
Pattern reset
selection
Resets the centrifuge sequence.
Note:
The drive must be stopped before reset is
possible.
DI3
Not selected
Not selected.
0
Reset now
Reset.
1
DI1
Reset through DI1.
2
DI2
Reset through DI2.
3
DI3
Reset through DI3.
4
DI4
Reset through DI4.
5
DI5
Reset through DI5.
6
DI6
Reset through DI6.
7
-
75.02
Manual halt
Shifts Centrifuge application to deceleration mode.
DI4
Not selected
Not selected.
0
Selected
Selected
1
DI1
Halt through DI1.
2
DI2
Halt through DI2.
3
DI3
Halt through DI3.
4
DI4
Halt through DI4.
5
DI5
Halt through DI5.
6
DI6
Halt through DI6.
7